Chapter 5 Troubleshooting 

THOR’s  ISO9001  quality  assurance  system  has  been  approved  by  the  CQC 

organization. We guarantee the products’ quality, reliability and stability. All THOR 

products haven passed all testing and manual inspections before they are shipped out. 

The  testing  and  inspection  scheme  already  covers  all  the  Optical,  Electronic  and 

Mechanical  criteria  which  have  been  published  by  THOR.  To  prevent  a  potential 

hazard, please strictly follow the operation conditions. 

 

Prevention Measures 

 

Installing the device in a place where the environmental temperature is 

between 0 to 45 °C 

 

Making sure the unit has plenty of ventilation for the heat-sink on the rear 

panel; and other heat-sink bores if necessary 

 

Checking the AC input within the power supply and ensure it is working, the 

connection is correctly installed before switching on device 

 

Checking the RF output levels to stay within a tolerable range, if it is 

necessary 

 

Checking all signal cables have been properly connected 

 

Frequently switching on/off device is prohibited; the interval between every 

switching on/off must be greater than 10 seconds. 
 

Conditions needed to unplug power cord 

 

Power cord or socket damage. 

 

Any liquid that got into the device. 

 

Any stuff that could cause a circuit short 

 

Device in damp environment 

 

Device has suffered from physical damage; i.e. it fell off a rack. 

 

Longtime idle. 

 

After switching on and restoring to factory setting, device still won’t work 

properly. 

 

Maintenance needed on device 

 
 

Содержание H-4HD-EMH

Страница 1: ...H 4HD EMH H 4HD EMS H 4HD EMHS 4 Channel SDI HDMI Pro DVB Contribution Encoder For ASI and IPTV User Manual 2017...

Страница 2: ...rt of this document may be reproduced in any form without the written permission of Thor Broadcast The contents of this document are subject to revision without notice due to continued progress in met...

Страница 3: ...ESCRIPTION 6 CHAPTER 2 INSTALLATION GUIDE 8 2 1 GENERAL PRECAUTIONS 8 2 2 POWER PRECAUTIONS 8 2 3 DEVICE S INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING 8 2 4 ENVIRONMENT REQUIREMENT 9 2 5 GROUNDIN...

Страница 4: ...t on mirrored BNC terminals The 4 encoded HDMI HD SDI programs will output through ASI and IP ports in MPTS or SPTS This powerful design allows you to distribute up to 1080p program streams in crystal...

Страница 5: ...or H 264 encoding 1 19 5Mbps for MPEG 2 encoding Rate Control Mode CBR VBR Audio encoding MPEG1 Layer II MPEG2 AAC MPEG4 AAC Dolby Digital AC3 Sample rate 48KHz Bit rate 64kbps 96kbps 128kbps 192kbps...

Страница 6: ...I SDI HDMI SDI 1 5 Appearance and Description Front Panel Illustration LCD window Power supply indicators Power Alarm Switch When only one power supply is connected or one of the power supplies fails...

Страница 7: ...EMH HDMI Input Module 1 Program input port 1 2 HDMI Input Module 2 Program input port 3 4 ASI output ports Power Supply Slot Power Switch Grounding Rear Panel H 4HD EMS SDI Input Module 1 Program inp...

Страница 8: ...er should be securely fastened do not open the cover of the products when the power is on After installation securely stow away all loose cables external antenna and others 2 2 Power Precautions When...

Страница 9: ...ing current limiting resistance 1M Floor bearing should be greater than 450Kg Environment Temperature 5 40 sustainable 0 45 short time installing air conditioning is recommended Relative Humidity 20 8...

Страница 10: ...smoothly General rule of them make sure the device is grounded when installing anywhere Always use copper wire When applied correctly the ground must be wrapped well to ensure maximum conduction so i...

Страница 11: ...onfig 1 1 Uptime Video Audio Program Info Video in status Service Provider Program name Service ID PCR PID Video PID Program output enable PMT PID Audio PID 4 Network 4 1 NMS 4 2 IP Stream 4 1 1 NMS I...

Страница 12: ...ing channel 3 3 General Settings for Main Menu Press LOCK key on the front panel to enter the main menu The LCD will display the following pages where you can configure the parameters for the Thor Enc...

Страница 13: ...nus 2 1 or 2 2 you could set the video audio parameters for the 2 HDMI programs respectively Video in Status Enter this menu to check the video input status Video Format The HDMI SDI encoders support...

Страница 14: ...Thor Broadcast Encoders offer Low Latency options MODE 1 is the Fastest NOTE The different combination of Video Format Video Bit rate Low Delay Mode the Resolution of signal source and Decoding optio...

Страница 15: ...e ranges from 64Kbps to 320Kbps Select one bit rate from the options provided Program Info Enable or disable the program output in the first sub menu and configure the other parameters in the rest sub...

Страница 16: ...ID ON ID Set the TS ID and Original Network ID in the 2 submenus The IDs are in hexadecimal form Output Bit rate Set the max output bit rate for the ASI MPTS out Range 0 100 Mbps NIT Insert Insert you...

Страница 17: ...e options TVCT CVCT close VCT ASI Output Copy a stream from the IP out streams 1 MPTS 8 SPTS to output through ASI 4 Network Network is divided into 2 parts NMS and IP Stream NMS Submenus under NMS ar...

Страница 18: ...ata Enable Null PKT Filter Output IP Output Port Service IP Subnet Mask NMS IP 192 168 000 136 Subnet Mask 255 255 255 000 Gateway 192 168 000 001 MAC Address 201012345678 Reset Password Yes NO Web NM...

Страница 19: ...Time out 30 s H 4HD EMS HD Encoder SW x xx HW x xx Choose yes to save settings Press ENTER to confirm Choose yes to restore the device into the last saved configuration Choose yes to restore the devi...

Страница 20: ...fault IP of this device is 192 168 0 136 We can modify the IP through the front panel Connect the pc and the device with net cable and use ping command to confirm they are on the same network segment...

Страница 21: ...nus Figure 2 Input 1 From the menu on left side of the webpage clicking Input 1 displays the information of the programs 1st 2nd from the SDI inputs TS indicators Green light indicates the TS is norma...

Страница 22: ...adcast com Figure 3 This column is for setting the 1st HD SDI input This column is for setting the 2ed HDSDI input program General Settings for the HDMI IN programs User can edit any item listed as ne...

Страница 23: ...t on the latency Please refer to the Appendix attached for detailed information For user to turn to refer detailed explanation of terms on this interface Click this button to apply the default setting...

Страница 24: ...r 2017 Tel 800 521 8467 Email sales thorfiber com www thorbroadcast com IP Output Click IP Output it will display the interface where to configure the output IP stream in MPTS or SPTS that will output...

Страница 25: ...CT Click VCT from the menu it will display the interface as Figure 6 where to set the VCT configuration Figure 6 MPTS 4 SPTS for the 4 programs respectively Supports 1 MPTS 4 SPTS IP outputs Click the...

Страница 26: ...gure 7 where to set the network info for the output TS Figure 7 Save Restore From the menu on left side of the webpage clicking Save Restore it will display the screen as Figure 8 where to save or res...

Страница 27: ...box it will restart the device automatically Figure 9 Update the Device Click Firmware from the menu it will display the screen as Figure 10 Here user can update the device by using the update file C...

Страница 28: ...ill display the screen as Figure 11 It displays the network information of the device Here user can change the device network configuration as needed Figure 11 Change Password When user clicks Passwor...

Страница 29: ...keyboard LCD while only the device IP address can be noted in the LCD window Backup Load Click Backup Load from the menu Backup Configuration To back up the device configuration file to a folder Resto...

Страница 30: ...H 4HD EMS EMH Thor Fiber 2017 Tel 800 521 8467 Email sales thorfiber com www thorbroadcast com Application Drawing...

Страница 31: ...H 4HD EMS EMH Thor Fiber 2017 Tel 800 521 8467 Email sales thorfiber com www thorbroadcast com...

Страница 32: ...ing sure the unit has plenty of ventilation for the heat sink on the rear panel and other heat sink bores if necessary Checking the AC input within the power supply and ensure it is working the connec...

Страница 33: ...800 521 8467 Email sales thorfiber com www thorbroadcast com Chapter 6 Packing List H 4HD EMS or EMH Encoder 1PC User Manual 1PC HDMI SDI Cables 4PCs Power Cord 1PC For Further Tech Support 1 800 521...

Отзывы: