Adjustments
Technical Manual LDK 5411 - Betacam SP Adapter
3-15
Sync amplitude
13. Adjust the sync, amplitude potentiometer fto obtain a sync. ampliatude of 286mV.
Measure at:
Adjust with:
Required result:
Correct:
CVBS out
ZR525
286mV
Y offset
14. Adjust the Y offset potentiometer to place the black bar at the 50mVdc level.
Measure at:
Adjust with:
Required result:
Correct:
X21-14A
ZR52
Black bar = 50mV
Y amplitude
15. Adjust the Y gain potentiometer to obtain an output amplitude of 1428mV.
Measure at:
Adjust with:
Required result:
Correct:
X21-14A
ZR528
1428mV
16. Switch off power and return encoder board to its position in the camera.
Encoder Board NTSC
0%
10
90
100
0.1V
2µS
VA+286mV
0%
10
90
100
0.2V
5µS
VA+1428mV
0%
10
90
100
0.2V
5µS
VA+1428mV
Содержание LDK 5411
Страница 6: ...iv Technical Manual LDK 5411 Betacam SP Adapter 02 36 2 ...
Страница 10: ...1 4 Technical Manual LDK 5411 Betacam SP Adapter Safety Instructions ...
Страница 18: ...2 8 Technical Manual LDK 5411 Betacam SP Adapter Installation ...
Страница 34: ...3 16 Technical Manual LDK 5411 Betacam SP Adapter Adjustments ...
Страница 36: ...5 2 Technical Manual LDK 5411 Betacam SP Adapter Wiring Diagrams ...
Страница 38: ...5 2 Technical Manual LDK 5411 Betacam SP Adapter Mechanical Exploded Views ...
Страница 39: ...Mechanical Exploded Views Technical Manual LDK 5411 Betacam SP Adapter 5 3 ...
Страница 40: ...5 4 Technical Manual LDK 5411 Betacam SP Adapter Mechanical Exploded Views ...
Страница 41: ...Parts Lists Technical Manual LDK 5411 Betacam SP Adapter 6 1 Section 6 Parts Lists ...
Страница 42: ...6 2 Technical Manual LDK 5411 Betacam SP Adapter Parts Lists ...