Adjustments
Technical Manual LDK 5411 - Betacam SP Adapter
3-7
B-Y amplitude
9. Adjust the B-Y gain potentiometer to obtain an output amplitude of 1050mV.
Measure at:
Adjust with:
Required result:
Correct:
X21-11A
ZR114
1050mV
BURST ADJUSTMENTS
Burst phase
10. Measure in second quadrant of vectorscope.
Adjust the input sensitivity potentiometer of the vectorscope so the burst vectors just touch the circle
graticule.
11. Adjust the burst phase potentiometer for 90° phase output.
Measure at:
Adjust with:
CVBS out
ZR722
Burst amplitude
12. Adjust the burst amplitude potentiometer to obtain a burst amplitude of 300mV.
Measure at:
Adjust with:
Required result:
Correct:
CVBS out
ZR717
300mV
Sc-H phase relationship
13. Switch vectorscope to internal synchronisation.
14. Adjust Sc-H phase potentiometer for 180°.
Measure at:
Adjust with:
Required result:
Correct:
CVBS out
ZR902
Encoder Board PAL
0%
10
90
100
0.2V
10µS
VA+1050mV
0%
10
90
100
0.1V
2µS
VA+300mV
20
40
R
60
80
0.7
100
120
20
43
0.3
g
YL
MG
cy
b
B
yl
G
r
CY
mg
75
100
U
V
0
0
5
-5
%
VOLT
Содержание LDK 5411
Страница 6: ...iv Technical Manual LDK 5411 Betacam SP Adapter 02 36 2 ...
Страница 10: ...1 4 Technical Manual LDK 5411 Betacam SP Adapter Safety Instructions ...
Страница 18: ...2 8 Technical Manual LDK 5411 Betacam SP Adapter Installation ...
Страница 34: ...3 16 Technical Manual LDK 5411 Betacam SP Adapter Adjustments ...
Страница 36: ...5 2 Technical Manual LDK 5411 Betacam SP Adapter Wiring Diagrams ...
Страница 38: ...5 2 Technical Manual LDK 5411 Betacam SP Adapter Mechanical Exploded Views ...
Страница 39: ...Mechanical Exploded Views Technical Manual LDK 5411 Betacam SP Adapter 5 3 ...
Страница 40: ...5 4 Technical Manual LDK 5411 Betacam SP Adapter Mechanical Exploded Views ...
Страница 41: ...Parts Lists Technical Manual LDK 5411 Betacam SP Adapter 6 1 Section 6 Parts Lists ...
Страница 42: ...6 2 Technical Manual LDK 5411 Betacam SP Adapter Parts Lists ...