THOMSON Electrak LL Скачать руководство пользователя страница 8

Thomson

Thomson Electrak

®

 LL Actuator - Installation Manual - 2020-11

8

4.4.3  Mounting orientation and forces

1.  The actuator can be mounted in any orientation and handle both pushing and pulling loads. 

2.  Always install actuator so that the force of the load acts in the center of the extension tube and the  

  rear adapter. 

3.  Only mount the actuator to the rear and front adapter mounting holes.

4.  Only use solid mounting pins and support them at both ends.  

5.  The mounting pins must be parallel to each other both radially and axially.

4.4.4  Cable connector cover plate 

1.  The cover plate is held in place by a screw (M3 with Torx T10 head) that can be accessed through  

  the hole in the top of the cover plate (a). Keep in mind to mount the actuator so that there is enough  

  clearance to access the screw with a tool!

2.  Once the cover plate is released it needs to be pushed about 20 mm (0.8 inch) in the direction of  

  the arrow symbol on the cover plate before it can be removed from the actuator (b). The connectors  

  are a part of the backside of the cover plate and can be accessed once the cover plate is removed.

3.  Make sure to put the cover plate back correctly and torque the screw to 1.2Nm (10.6 in-lb) to ensure  

  that the actuator cover plate and connectors are properly sealed.

           

YES

NO

Содержание Electrak LL

Страница 1: ...Thomson Electrak LL Electric Linear Actuator Installation Manual Edition 2020 11 www thomsonlinear com...

Страница 2: ...homson makes no representation or warranty as to the suitability of the product for any particular use or purpose For a copy of the entire warranty for this product that is contained in our standard t...

Страница 3: ...7 Support 4 2 Safety 5 2 1 Safety notes 5 3 Standards 5 3 1 EC Declaration of conformity 5 4 Installation 6 4 1 Product label 6 4 2 Terminology 6 4 3 Operation environment 6 4 4 Mechanical installati...

Страница 4: ...inal packaging supplied by Thomson The temperature during transportation and storage must be between 40 to 85 C 40 to 185 F Avoid shocks to the package If the package is damaged check the actuator for...

Страница 5: ...y and notify an appropriate person so that corrective actions can be taken Never open the actuator as that will compromise the sealing and the function of the actuator There are no serviceable compone...

Страница 6: ...manufacturing date and the designation of the actuator s in question You can also use the QR code on the label to directly access Electrak LL information on www thomsonlinear com 4 2 Terminology 4 3...

Страница 7: ...s access to the cable connector cover plate c so that it can be removed to allow access to the cable connector s section 4 4 4 3 The cable or cables d exit the cable slot at the rear of the actuator h...

Страница 8: ...able connector cover plate 1 The cover plate is held in place by a screw M3 with Torx T10 head that can be accessed through the hole in the top of the cover plate a Keep in mind to mount the actuator...

Страница 9: ...d using the hand wind is typically 4 6 Nm 35 50 in lb Always make sure to switch off the power to the actuator before using the hand wind Do not apply higher torque than 10 Nm 88 in lb to the hand win...

Страница 10: ...cable s have flying leads in one end for customer connections In the other end the cable s are integrated in to the cable connector cover plate c section 4 4 4 The plug in connector allows replacing...

Страница 11: ...ally have no problem delivering the inrush current Also contacts switches and relays must be sized appropriately to be able to handle the inrush current 4 5 6 Brake resistor If the unit is to operate...

Страница 12: ...e drop Relays or other coil operated devices should have spark protection to avoid interference Never work on the actuator or the wiring with the power switched on 4 6 2 Speed control by adjusting the...

Страница 13: ...ad 2 to Vdc and lead 1 to Vdc in the power cable If using a brake resistor it should be connetc between leads 2 and 3 in the power cable Make sure to use the correct type of resistor section 4 5 6 To...

Страница 14: ...r power supply can provide enough current to move the rated load The actuator when powered is causing my fuse to blow Fuse is not rated for current draw of the actuator Make sure that the fuse is rate...

Страница 15: ...Operating temperature limits standard units C F 40 to 85 40 to 185 Full load duty cycle 25 C see product label Restraining torque Nm lbf in 0 internally restrained Motor cable lead cross section mm2...

Страница 16: ...tching external end off stroke limit switch inputs 5 Cable option 1 0 3 m long cable 6 Rear adapter option M cross hole for 12 mm pin E cross hole for inch pin N forked cross hole for 12 mm pin F fork...

Страница 17: ...Thomson Thomson Electrak LL Actuator Installation Manual 2020 11 17...

Страница 18: ...anstad Phone 46 44 590 2400 Fax 46 44 590 2585 E mail sales scandinavia thomsonlinear com SOUTH AMERICA Brazil Thomson Av Jo o Paulo Ablas 2970 Jardim da Gl ria Cotia SP CEP 06711 250 Phone 55 11 4615...