DFT-6600 Battery Charger-Discharger Users Manual
19
Chapter 4 Functions and operating procedures
4.1. Starting Boot
Press the power switch on the back of the tester to activate the tester and enter the main menu of the DFT-6600
Tester. The main menu is as follows:
4.2. Battery Discharge
In the main menu, press the icon "Discharge Test" to enter the discharge settings interface.
At this point, you need to set the site No., Battery string No., Voltage level, Battery type, batteries No., Nominal
capacity. Discharge capacity; the parameters of the stop setting are automatically filled in, or you can also modify it
yourself.
Finally, according to the actual situation, tick select to detect single-cell, or the single-cell is not monitored if not
tick the single-cell means.
After set the discharge parameters and press the [Start] key to enter the discharge state.