TA04583 B Page 5 of 8
4.0
MAINTENANCE
The tool is completely sealed, and requires very little daily maintenance. Compliance with the following
recommendations, should help to maintain the optimum performance of the tool:
THOROUGH CLEANING
UNINTERRUPTED USE
4.1
4.2
Dust, sand and dirt are a danger for any hydraulic device
After every use, the tool must be wiped with a clean cloth
taking care to remove any residue, especially close to
moveable parts
The tool should be allowed to cool down following
a series of uninterrupted, successive uses If a fully
charged battery becomes exhausted in one session,
wait five minutes before replacing the battery and
continuing use
STORAGE
(Refer to Fig. 7)
4.3
When not in use, the tool should be stored and transported in the
plastic case to prevent damage This case is suitable for storing
the tool and accessories
Plastic Case: size 19 5 x 14 5 x 5 4 inches, (497 x 370 x 137 mm)
weighs 5lbs (2 3 kg)
(Continued)
Green flashing
(right-hand LED): The battery is fully charged and the charger automatically switches over to the trickle-
charge mode. The battery can be left indefinitely in the charger without sustaining any damage. Overcharging is impossible.
Red flashing
(right-hand LED): The safety elements are defective or the battery is too hot or too cold. The battery should be
removed from the charger so that it can return to its proper temperature range.
Continuous red
(right-hand LED): The battery is defective.
•
CHARGING TIMES
The following table lists the various charging times (the charging time depends on the depth of
discharge). A new or seldom used battery will achieve full power after 5 charge/discharge cycles.
* To charge these batteries use the CBA96-144 adapter (Refer to Fig. 6)
•
WARNING
The left-hand LED flashes red to indicate a charger fault.
A charger malfunction has occurred and it is not possible to continue charging.
Do not use the charger to charge other batteries.
If batteries are new or have not been used for some time, it is quite likely that they will not reach their nominal capacity. This
is not a fault and is normal under these circumstances.
Full capacity will be reached after about the 5 charge/discharge cycles.
The charger monitors the battery-pack temperature. Batteries with temperatures above 65°C or below 5°C will not be
charged.
The charger is designed to charge both Ni-Cd and Ni-MH batteries: with Ni-MH batteries a more noticeable heating of the
cells will occur. This is not a fault.
Battery Type
Nominal capacity (Ah)
Maximum Charging Time
CFC120Y
NI-Cd
2.0
55 min
NI-MH (CB9620H)*
2.0
55 min
NI-MH (CB9630H)*
3.0
85 min
NI-MH (CB1430H)
3.0
85 min
Fig. 7