thomann Tri Flood MK II Скачать руководство пользователя страница 39

Channel

Value

Function

0…31

Off

32…63

Slowly increasing brightness

64…95

Slowly decreasing brightness

96…127

Slowly alternating increasing brightness, then slowly decreasing

128…159

Smooth colour change, speed depends on channel 5

160…191

Automatic colour change (3 colours), speed depends on channel 5

192…255

Sound control

7

0…255

Dimmer (0 % to 100 %)

Operation

 

 

Tri Flood MK II 15×15 W RGB

39

Содержание Tri Flood MK II

Страница 1: ...Tri Flood MK II 15 15 W RGB LED floodlight user manual...

Страница 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 23 01 2013...

Страница 3: ...tions and operating elements 19 7 Operation 22 7 1 Starting up the device 22 7 2 Main menu 22 7 3 Menu overview 32 7 4 Functions in DMX mode 1 33 7 5 Functions in DMX mode 2 34 7 6 Functions in DMX mo...

Страница 4: ...7 9 Functions in DMX mode 6 38 8 Technical specifications 40 9 Troubleshooting 41 10 Cleaning 43 11 Protecting the environment 44 Table of contents LED floodlight 4...

Страница 5: ...hat it is available to all persons using this device If you sell the device include the manual for the next owner Our products are subject to a process of continuous development We therefore reserve t...

Страница 6: ...combination of symbol and signal word indicates a possible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indica...

Страница 7: ...Warning signs Type of danger Warning suspended load Warning danger zone General notes Tri Flood MK II 15 15 W RGB 7...

Страница 8: ...nt physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is respon...

Страница 9: ...viceable parts inside DANGER Electric shock caused by short circuit Do not modify the mains cable or the plug Failure to do so could result in electric shock death or fire If in doubt seek advice from...

Страница 10: ...ot cover the device nor any ventilation slots Do not place the device near any direct heat source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for i...

Страница 11: ...the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and...

Страница 12: ...als in discos or for architectural and garden illumination Special features of this device n 15 tricoloured LEDs 15 W each n Control via DMX 5 different modes and via buttons and display on the unit n...

Страница 13: ...n packaging material suitable for transport or storage respectively You can install the device on the wall ceiling or floor A mounting bracket is included in the package WARNING Risk of injury caused...

Страница 14: ...ture must always be below 40 C 104 F NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed...

Страница 15: ...e cables Never connect the DMX output to audio devices such as mixers or amplifiers The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX input Please refer to the drawing and...

Страница 16: ...5 Starting up Establish all connections as long as the unit is switched off Use the shortest possible high quality cables for all connections Starting up LED floodlight 16...

Страница 17: ...device Connect the output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is terminated...

Страница 18: ...nchronized show This function is ideal when you want to start a show immediately Connect the DMX output of the master device to the DMX input of the first slave device Then connect the DMX output of t...

Страница 19: ...6 Connections and operating elements Rear panel Connections and operating elements Tri Flood MK II 15 15 W RGB 19...

Страница 20: ...Decreases the displayed value by one 5 POWER IN Cable with special threaded coupling connector for mains power connection 6 POWER OUT Cable with special threaded coupling connector to feed further un...

Страница 21: ...with DMX outdoor threaded coupling connector as DMX output for further units 10 DMX IN Cable with DMX outdoor threaded coupling connector as DMX input Connections and operating elements Tri Flood MK I...

Страница 22: ...utton to activate the main menu and select an operating mode Use the buttons UP and DOWN to change the respectively shown value When the display shows the desired value press the MODE button If you do...

Страница 23: ...1 A512 When the display shows the desired value press the MODE button to confirm the selection and return to the parent menu To return there without changes wait a minute Make sure that the set DMX ad...

Страница 24: ...DISP ON The backlight of the display stays permanently on n DISP OFF The backlight of the display turns off when no button is pressed for ten seconds n TEMP xxx The display shows the temperature insi...

Страница 25: ...ows the desired value press the MODE button to confirm the selection and to return to the parent menu To return there without any changes wait a minute Press the MODE button repeatedly until the top r...

Страница 26: ...he respective basic colour in the range from 0 to 100 This brightness setting of the basic colours overrides the settings that can be con trolled by DMX Press the MODE repeatedly until the top row of...

Страница 27: ...els n MODE4 DMX mode 4 five channels n MODE5 DMX mode 5 seven channels n MODE6 DMX mode 6 seven channels n SLAVE Slave operation this setting is only relevant if the unit is operated as slave by a mas...

Страница 28: ...table Programme Show 001 Colour chase three colours 002 Colour chase seven colours 003 Colour junction three colours 004 Colour junction seven colours 005 Coloured strobe light strobe three colours 0...

Страница 29: ...ing is only relevant if the unit is not controlled via DMX When the display shows the desired value press the MODE button to confirm the selection and return to the parent menu To return there without...

Страница 30: ...erature the brightness is reduced As soon as the temperature exceeds 48 C the fan turns on n POWER The brightness of the LEDs is always set at 100 as long as the temperature inside the unit is below 7...

Страница 31: ...t press any button for 10 seconds the keys will be locked n 30S If you don t press any button for 30 seconds the keys will be locked When the display shows the desired value press the MODE button to c...

Страница 32: ...7 3 Menu overview Operation LED floodlight 32...

Страница 33: ...7 4 Functions in DMX mode 1 Channel Value Function 1 Automatic colour change 0 6 Blackout 7 13 Macro 1 245 255 Macro 36 Operation Tri Flood MK II 15 15 W RGB 33...

Страница 34: ...7 5 Functions in DMX mode 2 Channel Value Function 1 Automatic colour change 0 6 Blackout 7 13 Macro 1 245 255 Macro 36 2 0 255 Dimmer 0 to 100 Operation LED floodlight 34...

Страница 35: ...y red 0 to 100 2 0 255 Intensity green 0 to 100 3 0 255 Intensity blue 0 to 100 7 7 Functions in DMX mode 4 Channel Value Function 1 0 255 Intensity red 0 to 100 2 0 255 Intensity green 0 to 100 3 0 2...

Страница 36: ...effect 8 255 Strobe effect increasing speed 1 12 Hz 5 0 255 Dimmer 0 to 100 7 8 Functions in DMX mode 5 Channel Value Function 1 0 255 Intensity red 0 to 100 2 0 255 Intensity green 0 to 100 3 0 255...

Страница 37: ...asing brightness 64 95 Slowly decreasing brightness 96 127 Slowly alternating increasing brightness then slowly decreasing 128 159 Automatic colour change typ 1 160 191 Automatic colour change typ 2 3...

Страница 38: ...55 Intensity green 0 to 100 3 0 255 Intensity blue 0 to 100 4 Automatic colour change 0 7 Macro 1 247 255 Macro 36 5 Strobe effect 0 7 Full brightness no strobe effect 8 255 Strobe effect increasing s...

Страница 39: ...rightness 96 127 Slowly alternating increasing brightness then slowly decreasing 128 159 Smooth colour change speed depends on channel 5 160 191 Automatic colour change 3 colours speed depends on chan...

Страница 40: ...d RGB Dispersion angle approx 40 Number of DMX channels 1 2 3 5 or 7 Operating voltage supply AC 230 V 50 Hz Power consumption 270 W Protection class IP65 Dimensions W D H 445 mm 310 mm 200 mm Weight...

Страница 41: ...MX cables and do not use ordi nary microphone cables Never connect the DMX output to audio devices such as mixers or amplifiers In the following we list a few common problems that may occur during ope...

Страница 42: ...address settings and the DMX polarity 3 Try using another DMX controller 4 Check to see if the DMX cables run near or alongside to high voltage cables that may cause damage or interfer ence to DMX int...

Страница 43: ...y of cleaning depends on the operating environment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using normal g...

Страница 44: ...recycling Please follow the notes and markings on the packaging This device is subject to the European directive 2002 96 EC Do not dispose of the device with your normal household waste Dispose of th...

Страница 45: ...Notes Tri Flood MK II 15 15 W RGB 45...

Страница 46: ...Notes LED floodlight 46...

Страница 47: ......

Страница 48: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...

Отзывы: