background image

Warning signs

Type of danger

Warning – danger zone.

General notes

 

 

digital power amplifier

6

Содержание the t.amp pro D4-500

Страница 1: ...D4 500 digital power amplifier user manual...

Страница 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 13 08 2012...

Страница 3: ...ety instructions 7 3 Features 12 4 Installation and starting up 13 4 1 Pin assignment 14 5 Connections and operating elements 18 6 Power consumption 23 7 Technical specifications 24 8 Protecting the e...

Страница 4: ...s available to all persons using this device If you sell the device to other users be sure that they also receive this manual Our products are subject to a process of continuous development We therefo...

Страница 5: ...UTION This combination of symbol and signal word indicates a possible dangerous situation that can result in minor injury if it is not avoided NOTICE This combination of symbol and signal word indicat...

Страница 6: ...Warning signs Type of danger Warning danger zone General notes digital power amplifier 6...

Страница 7: ...cient physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is res...

Страница 8: ...iceable parts inside DANGER Electric shock caused by short circuit Always use proper ready made insulated mains cabling power cord with a pro tective contact plug Do not modify the mains cable or the...

Страница 9: ...ritical can cause hearing damage Decrease the volume level immediately if you experience ringing in your ears or hearing impairment If this is not possible keep a greater distance or use suffi cient e...

Страница 10: ...the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in...

Страница 11: ...above and below the power amplifier Therefore never place sensitive devices such as pre amplifiers radio transmission systems or tape decks directly above or below the power amplifier When installing...

Страница 12: ...3 Features n Output power 4 500 W 4 W 4 250 W 8 W n 4 inputs 4 outputs n Frequency response 20 Hz to 20 kHz n 19 rackable 1 RU installation depth 240 mm Features digital power amplifier 12...

Страница 13: ...ect the device against vibration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Establish a...

Страница 14: ...In the following we will give you an overview of the various options Drawings and tables indicate the XLR pin assign ment Balanced wiring 1 Ground shielding 2 Positive signal 3 Negative signal XLR co...

Страница 15: ...Signal 3 Bridged to pin 1 Drawings and tables indicate the pin assignment of 1 4 phone plugs to be used Unbalanced wiring of a TS plug 1 Signal 2 Ground shielding 1 4 phone sockets for signal inputs...

Страница 16: ...nbalanced wiring of a TRS plug 1 Signal 2 3 Ground shielding Balanced wiring of a TRS plug 1 Positive signal 2 Negative signal 3 Ground shielding Installation and starting up digital power amplifier 1...

Страница 17: ...The drawing alongside shows the pin assignment of the lockable NL4 mounting connectors NL4 mounting connectors Installation and starting up D4 500 17...

Страница 18: ...5 Connections and operating elements Front panel Connections and operating elements digital power amplifier 18...

Страница 19: ...rols CH A to CH D and if required check the wiring If these LEDs are lit without an input signal is present there is an error In this case disconnect the speakers from the power amplifier and turn the...

Страница 20: ...Once the LEDs turn off the device is operational 6 LEDs Thermal Over temperature indicator for the channels CH A to CH D These LEDs light up when the respective heat sink exceeds a certain temperatur...

Страница 21: ...Rear panel Connections and operating elements D4 500 21...

Страница 22: ...of each other Parallel the inputs of a channel pair are interconnected and Bridge two channels are interconnected to form one channel with double output 12 Pushbutton Lift Ground Use the Ground Lift...

Страница 23: ...pending on the output power level RMS value ARMS Load 1 8 power pink noise 1 3 power pink noise Full power sine wave 8 W 4 130 W 1 3 A 190 W 1 9 A 640 W 4 2 A 4 W 4 180 W 1 6 A 420 W 3 1 A 1200 W 7 4...

Страница 24: ...kHz Slew rate 1 kHz 26 V ms THD 0 1 typical DIM 30 0 1 3 15 kHz 15 kHz Crosstalk 75 dB ref 1 kHz 10 rated power Frequency response 20 Hz 20 kHz 2 dB 1 dB ref 1 kHz Input impedance 20 kW balanced 10 k...

Страница 25: ...ltage temperature short circuit Undervoltage overcurrent lim iter Operating voltage supply AC 230 V 50 60 Hz Power consumption see Chapter 6 Power consumption on page 23 Dimensions 1 RU in a 19 rack i...

Страница 26: ...cling Please follow the notes and markings on the packaging This device is subject to the European directive 2002 96 EC Do not dispose of the device with your normal household waste Dispose of this de...

Страница 27: ......

Страница 28: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...

Отзывы: