7-13
KRF
7. Installation and Operation
7.
Installation and Operation
7. Installation and Operation
7. Fasten the bolts.
F
asten hexagon socket
head cap screw using the specified tightening torque. (plain washer, 4
holes)
Please measure it by the tensimeter once again after fastening the bolt.
Model number
Intermediate flange type
Bolt size
Tightening torque [N·cm]
KRF4R
WM, WN, WP, WQ
M3 × 6L
125
KRF5R
WM, WN, WP, WQ
M3 × 6L
125
KRF6R
WP, WQ
M3 × 6L
125
Bolt type: Hexagonal-socket-he
ad type bo
lt
Fasten the bolt