![THK CKSF Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/thk/cksf/cksf_instruction-manual_1107524032.webp)
8.
Maintenance
8-2
CKSF
8. Maintenance
8-3
Daily inspection
8-4
Periodical inspection
z
Before operating the product, visually check any exterior damage or stain.
z
Check the grease state (stain, etc.). If the grease is significantly stained, wipe off the
grease, and then supply new grease. (Supply the new grease until it comes out from the
inner block, and exhaust the stained grease. )
z
Check whether abnormal noise or vibration occurs during operation. If abnormal noise
or vibration occurs, immediately stop the machine and inspect the state of the product.
Insufficient lubrication or loosening of a mounting bolt can be a cause of abnormal noise or
vibration. Check for insufficient lubrication or loosening of a mounting bolt.
z
Check the strip seal for dirt or adhesion of foreign material.
Adhesives, paints or other viscous items or solids sticking to the strip seal or other parts might
cause the slider to malfunction or damage the strip seal. If it becomes dirty, wipe off the dirt using
a clean waste cloth soaked with alcohol-based detergent.
z
Check the strip seal for scratches, pits or dents.
Use of the strip seal in this state may cause early breakage or other damages. The strip seal must
be replaced when it is scratched or dented.
z
Perform more detailed inspection approximately once every 3 to 6 months.
· Check the lubrication state, and then clean the product and replenish the grease.
· Inspect whether each mounting bolt has loosened, and if any of them has loosened, retighten it.
z
For the suction port, check the following and replace it as needed:
1) Scratch, dent, wear, and corrosion
2) Air leaks
3) Twist, crush, or distortion of a tube
4) Hardening, deterioration, or softness of a tube
z
Visually check abnormal wear, scratches, or cracks on the surface of the strip seal.
· If you find any abnormalities, replace the strip seal.
· For the replacement procedure, see “Replacement of the strip seal procedure”.
www.thk.ru
тел. +7(499) 703-39-86