1.9.2 Sequence of a gas alarm
If an assigned wireless gas alarm sends out an alarm signal because a critical
gas concentration has been reached, or a gas alarm which is connected to the
gas alarm input gives an alarm, this will signal an alarm whether the system
is armed or not.
The siren sounds for about 30 seconds with short interruptions.
Depending on the vehicle type, the horn also sounds for about
30 seconds.
The vehicle indicators flash for about 180 seconds.
The status LED flashes for about 180 seconds.
If the cause of the alarm is not eliminated (critical gas concentration),
the vehicle indicators and the status LED will start to flash again until the
gas concentration has reached a noncritical level.
1.9.3 Interrupting a burglary alarm with the remote key fob
The “unlock” button interrupts the alarm or disarms the system.
It may be necessary to close the cab doors, depending on the vehicle type.
The vehicle indicators flash once or twice (depending on the vehicle type),
the interior beeper sounds 1 long and 2 short tones (disarmed).
Status LED flashes to indicate the corresponding cause of the alarm (see Page 6).
1.9.4 Interrupting a gas alarm with the remote key fob:
The “unlock” button interrupts the alarm or disarms the system.
If the alarm is triggered with the system disarmed, the latter must be armed
first (see 1.1) in order to interrupt the alarm afterwards with “unlock”.
It may be necessary to close the cab doors, depending on the vehicle type.
The vehicle indicators flash once or twice (depending on the vehicle type),
the interior beeper sounds 1 long and 2 short tones (disarmed). Status LED
flashes to indicate the corresponding cause of the alarm (see Page 6).
1.9.5 Interrupting a burglary alarm with the wireless remote control:
Any button interrupts the alarm or disarms the system.
It may be necessary to close the cab doors, depending on the vehicle type.
The vehicle indicators flash once or twice (depending on the vehicle type),
the interior beeper sounds 1 long and 2 short tones (disarmed).
Status LED flashes to indicate the corresponding cause of the alarm (see Page 6).
WiPro III Operating Instructions
Page 4
GB
Содержание WiPro III
Страница 65: ...Notes...
Страница 66: ...Notes...