Page 16
TLX160 Matrix Switch Product Manual
thinklogical
Rev. E, February, 2018
Control Server
must be at
192.168.13.9
, and the
Control Clients
can then be set to any other
addresses in the
192.168.13.X
subnet.
If static IP addresses for the control server and its clients are not possible, then the control server will
require two (2) network interfaces, with one interface set to the static address
192.168.13.9
and
dedicated to the TLX160 KVM Matrix Switch(s), while the other network interface can be configured as
required by the facility's network administrator
External Control CPU Minimum Requirements
The External Control CPU must meet the following minimum requirements
(including requirements
for
using Thinklogical’s System Management Portfolio)
:
•
System Management Interface
package requires
Debian
32 or 64 bit.
•
Configurator
and
Hot Key Manager
run on Linux (RedHat 32 & 64 bit,
Debian 32 & 64 bit or Windows XP, 7, and 8).
•
RAM
(minimum):
Linux:
1GB
Windows:
4GB
OSX:
4GB
•
VIDEO:
Works with all video adapters. (Not required if the computer is used as a headless server.)
•
KEYBOARD/MOUSE:
Works with any keyboard/mouse/touchpad. (Not required if the computer is
used as a headless server.)
•
NETWORK:
One port minimum, although two ports are recommended for security considerations.
•
DISK SPACE:
Thinklogical programs typically use less than 40 MB.
•
SERIAL PORT:
1 optional RS-232 serial port (Crestron/AMX serial access)
Pluggable SFP+ Modules
Each Input and Output card contains rows of SFP+ modules that serve as
the fiber-optic couplers for the fiber cables to and from the Thinklogical
transmitter and receiver extenders. Individual cards can be removed for easy
access to the SFP+ modules.
The SFP+ Optical Module is an 8Gbs Short-Wavelength Transceiver
designed for use in bi-directional Fiber Optic Channel links. The modules
have LC-type connectors, are hot-pluggable and operate on 3.3VDC.
Always use
dust caps
to protect against dust and damage when a fiber
optic connector is not attached to its coupling device (fiber optic
equipment, bulkheads, etc.). All Thinklogical Matrix Switch SFPs are fully populated with dust
plugs upon shipment.
Note:
It is good practice to immediately install dust plugs in unused SFP modules and on
the ferrules of unconnected fiber-optic cables.
Each fiber-optic TLX160 I/O Card has either 10 SFP+ Modules
, each mounted within a grounded
metal enclosure. Each SFP is locked into its enclosure with a built-in latch handle that can be opened for
removal or locked for installation (right).
The latch handle spans the two LC ports. Arrows printed on the handle indicate which port is an INPUT
(
) and which is an OUTPUT (
).
SFP+ Latch Closed