Thinklabs Rhythm ds32a Скачать руководство пользователя страница 14

Service and Warranty

The Thinklabs ds32a Digital Stehtoscope is warranted against manufacturing or materials 
defects for a period of one year from the invoice date. If a material or manufacturing defect 
occurs within the warranty period, repairs will be performed free of charge upon returning 
the  device  to  Thinklabs.  The  warranty  will  be  voided  in  cases  of  abuse,  excessive  or 
inappropriate use conditions, or accidental damage to the product. Thinklabs may, at it’s 
sole  discretion,  replace  the  product  with  a  suitable  equivalent  model.  The  warranty  is 
transferable at Thinklabs’ discretion only.

For maintenance, repair, service and contact information, visit the Thinklabs website at 
www.thinklabsmedical.com, and check the Support page. Before shipping the product for 
repair, please contact Thinklabs first, at 

[email protected]
or (800)918-1088.

Please quote the serial number, located inside the battery compartment when contacting 
us.

To have the product repaired, ship the product in suitably protective packaging, with name, 
return  address,  daytime  telephone  number  and/or  email  address,  a  description  of  the 
problem, and a copy of the purchase invoice, to:

Thinklabs inc. 
Attn: Service
6571 South Pontiac Court
Centennial, CO 80111

Sony Products are serviced and guaranteed by Sony Corporation. See the IC Recorder Manual 
for details. For service on Sony products, contact:
Sony 1-800-222-7669
http://www.sony.com

Page 14

Содержание Rhythm ds32a

Страница 1: ...Thinklabs User s Manual Recording Package Sony ICD UX71 81 Rhythm ds32a High Resolution Auscultation...

Страница 2: ...ltaneously connected to other equipment Recording attachments that connect to an iPod are permissible since they are powered by the iPod Stethoscope connected to a notebook computer as long as the com...

Страница 3: ...rence Controls and Display 7 Initial Setup 9 Connecting the ds32a Stethoscope to Sony IC Recorder 10 Recording Sounds Tips for Best Sound Quality 11 Playback of Sounds Selecting Headphones 12 Transfer...

Страница 4: ...n and ambient noise coupling through air borne transducers or tubing The EmD is pressure modulated By subtle variation of Probe pressure amplitude and frequency response can be tuned to listen to spec...

Страница 5: ...Cable 2 x Extra Eartips Quick Reference Guide Sony ICD UX71 81 Digital Audio Recorder Thinklabs Phonocardiography Software available for free download on Thinklabs website http www thinklabsmedical c...

Страница 6: ...ly Release Preset Modes 1 Set ds32a in your preferred modes ALL Modes are memorized 2 Set auto shutoff time Click the Power key the number of minutes ds32a should stay on before auto shutoff 2 3 4 or...

Страница 7: ...p 2 Setting the Clock Refer also to the Sony IC Recorder Operating Instructions Recording Messages section To record from the ds32a Digital Stethoscope the Sony Recorder should be set to the settings...

Страница 8: ...t 2 SECONDS and then place it on the Mitral area the two recordings will automatically be saved as separate files This can be very convenient but you do need to be aware of this automation to avoid co...

Страница 9: ...s shown below 4 As shown adjust the VOLUME CONTROL on the ds32a to the maximum level 10 if you find that recordings are distorted or clipped peaks distorted adjust the VOLUME down to a level which is...

Страница 10: ...to find a preferred Volume level that optimizes recording and listening clarity When you are recording optimize for recording quality Generally higher volume settings produce better recording quality...

Страница 11: ...ck 2 Turn OFF the ds32a by holding the POWER key on the ds32a for 2 seconds and releasing Do not hold the ds32a POWER key for more than 5 seconds This performs a different function Playback of Sounds...

Страница 12: ...er quickly and easily The files on the Sony ICD UX71 81 are recorded using MP3 format If you set the recording quality to SP the bit rate is sufficiently high that sound quality will be suited to reco...

Страница 13: ...iding you with complete control over signal processing functions Experiment with each setting to select the best for each situation Diaphragm Pressure and Skin Contact The ds32a Probe uses Electromagn...

Страница 14: ...e repair service and contact information visit the Thinklabs website at www thinklabsmedical com and check the Support page Before shipping the product for repair please contactThinklabs first at serv...

Страница 15: ...tion EmD Electromagnetic Diaphragm ANR2 are all trademarks of Thinklabs Medical LLC Centennial CO 80111 http www thinklabsmedical com service thinklabsmedical com 800 918 1088 6571 South Pontiac Court...

Отзывы: