INSTALLATION
The installation must be carried out by a suitably
qualified person, in accordance with the current
version of the following.
o
AS/NZS 3000: 2007 Wiring Regulations
o
2010 Electricity Safety Regulations
Electrical connection
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
This appliance is provided with a 15A 3-pin plug for use with a
suitable 15A GPO placed in an easily accessible position adjacent
to the appliance. The outlet must still be accessible even when
your oven is located in its housing.
o
To connect the oven power cord, loosen and remove the cover
on the terminal block, in order to gain access to the contacts
inside. Make the connection, securing the cord in place with the
cable clamp provided and then immediately close the terminal
block cover again.
o
If you have to change the oven power cord, the earthing
(yellow/green) conductor must always be 10 mm longer than the
line conductors.
o
Care must be taken to ensure that the temperature of the mains
supply cable does not exceed 50°C.
o
If the mains supply cable is damaged, then it must be replaced
by an appropriate replacement which can be obtained from the
Spares Department.