Any installation work must be 

carried out by a qualified 
electrician or competent person. 
 

o

 

The hood must be installed in 

accordance with the installation 
instructions and all measurements 
followed. 
 

o

 

 If the cooker hood is 

installed for use above a gas 
appliance then the provision for 
ventilation must be in accordance 
with the Australian Standard AS 
5601. 
 

o

 

It is dangerous to alter the 

specifications or to modify this 
product in any way.  Do not tamper 
with it or attempt to alter it in the 
attempt to customise it further. 
 

o

 

When installing the hood, 

ensure that the following 
recommended distances are being 
observed between the cooker top 
and the bottom of the cooker hood: 

 

9

 

Electric cookers:

  

700 

mm 

9

 

Gas cookers: 

  

700 

mm 

9

 

Coal/ oil cookers:

  

800 

mm 

 
 
 
 
 
 

* NOTE - DO NOT SET YOUR 
COOKER HOOD LESS THAN  
600 mm ABOVE YOUR 
COOKER! 

 

o

 

When installed between 
adjoining wall cabinets, 
the cabinets must not 
overhang the hob and 
their undersides must be 
at least 50 mm off from 
the hob edges. 

 

o

 

The edges of the cooker 
hood are sharp – be 
mindful of this as you 
handle your appliance, 
especially during 
installation and cleaning. 

DO

 

NOT

 

CLEAN

 

IN

 

BEHIND

 

THE

 

GREASE

 

FILTERS! 

 

o

 

If the room where the 
cooker hood is to be used 
contains a fuel burning 
appliance such as a 
central heating boiler 
then its flue must be of 
the sealed or balanced 
flue type. 

 

o

 

If other types of flue or 
appliances are fitted, 
ensure that there is an 
adequate supply of air in 
the room. 

 

o

 

When the hood is being 
used in its extractor 
function, ensure that the 
ducting is fire retardant 
and that there are no 
bends sharper than 90 
degrees as this will 
reduce the efficiency of 
the hood. 

 

Important Safety Information: 

Please Read this before installing & using.

 

Содержание GEH6019

Страница 1: ...OTE This User Instruction Manual contains important information including safety installation points which will enable you to get the most out of your appliance Please keep it in a safe place so that it is easily available for future reference ...

Страница 2: ...set and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and care manual thoroughly to familiarize yourself with the installation and operation requirements of your appliance to ensure optimum performance We also carry a complete range of spare parts for all Thin...

Страница 3: ...ATION 3 4 CARING FOR THE ENVIRONMENT 5 USING YOUR COOKER HOOD 6 MAINTAINING AND CLEANING YOUR COOKER HOOD 7 9 INSTALLATION INSTRUCTIONS 10 11 ELECTRICAL CONNECTION 10 INSTALLING THE COOKER HOOD 11 TROUBLESHOOTING 12 CONDITIONS OF GUARANTEE 13 HT 11 02 11 CONTENTS ...

Страница 4: ... Electrical button control operation 3 speeds 2 metallic grease filters 2 lights Extraction capacity 750 m hr Optional Extra 1 x Pair of S1 Carbon filters for air recirculation NOTE PLEASE NOTE THAT YOUR COOKER HOOD CAN BE USED EITHER IN RECIRCULATION MODE OR IN EXTRACTION MODE TO USE THE HOOD IN RE CIRCULATION MODE YOU WILL NEED TO FIT THE CARBON FILTER IF YOU WANT TO USE YOUR COOKER HOOD IN EXTR...

Страница 5: ...m NOTE DO NOT SET YOUR COOKER HOOD LESS THAN 600 mm ABOVE YOUR COOKER o When installed between adjoining wall cabinets the cabinets must not overhang the hob and their undersides must be at least 50 mm off from the hob edges o The edges of the cooker hood are sharp be mindful of this as you handle your appliance especially during installation and cleaning DO NOT CLEAN IN BEHIND THE GREASE FILTERS ...

Страница 6: ...hese instructions o Remember that when in extraction mode your cooker hood is removing air from your room Ensure that proper ventilation measures are being observed Note that it removes odours from your room not steam o Warning Always ensure that the cooker hood has been disconnected from the power supply before carrying out any work on the hood including replacing light bulbs o If the supply cord...

Страница 7: ...xcessively greasy Never flambé cook under this cooker hood Note Before discarding an old appliance switch off and disconnect it from the power supply Cut off and render any plug useless Cut the cable off directly behind the appliance to prevent misuse This should be undertaken by a competent person CONFORMITY TO W E E E DIRECTIVE Environmental Note ...

Страница 8: ...orm separate functions You will need to understand what these buttons do before you attempt to use your cooker hood Note The hood should be switched on at least as soon as you start cooking It is a good idea to have had it running for 5 minutes prior to cooking and at least 15 minutes after you have finished cooking KEY W Motor operation o low speed mid speed high speed U Light on off button This ...

Страница 9: ...ed intervals Build up could cause a fire hazard  Never take out the grease filters and attempt to clean the space above where they are set ________________________________________________ Anti Grease Grille  Your cooker hood includes an anti grease grille which helps absorb vapour suspended grease particles to protect your kitchen furniture from greasy residues  The metal grille may become infl...

Страница 10: ... them for about one hour in hot water with a grease loosening detergent then rinse off thoroughly with hot water 9 Repeat the process if needed Refit the grease grille once it has dried 9 Refit the grease grilles when dry Let the filter grilles dry thoroughly before refitting them Maintenance Cleaning the Anti grease Filters ...

Страница 11: ...l operation when in recirculation mode Before starting to fit the carbon filter turn the omni polar switch OFF Changing the Carbon Filter Note carbon filters cannot be cleaned 1 Remove the grease filter grilles 2 Remove the old carbon filter by twisting it anticlockwise until it unlatches from the side of the fan motor 3 Place the new carbon filter which has two fixing tongues turning clockwise so...

Страница 12: ... power cable must be fitted upstream from the electrical connection using an omni polar switch with a contact distance of at least 3mm NOTE UK only WARNING THIS APPLIANCE MUST NOT BE EARTHED It should only be connected by a competent person using fixed wiring via a DOUBLE POLE SWITCHED FUSED SPUR OUTLET We recommend that the appliance is connected by a qualified electrician who is a member of the ...

Страница 13: ...he centre distance of hole in the back of the cooker hood 3 Insert the nut into the holes 4 Insert the screws into the nuts and tight 5 Put up the cooker hood onto the fixed screws A 65cm 75cm 496 90 Way two Mounting under a wall unit 1 Drill 6 holes of 4mm diameter at the bottom of the hanging cupboard 2 Put the one way valve on the cooker hood then install the cooker hood on the bottom of the cu...

Страница 14: ...12 3 Install the adjusted board on the bottom of the hood in order to keep out the gap between hood back and cupboard B 2 54 516 12 ...

Страница 15: ...is not set high enough The grease filter is dirty The kitchen is not ventilated well enough If the hood is set for recirculation check that the carbon filters have not expired If the hood is set for extraction check that the ducting and outlets are not blocked The cooker hood has switched off during operation The safety cut out device has been tripped Turn off the hob and then wait for the device ...

Отзывы: