Figure   15   operational   status   dashboards   

ThingsLog

ТМ

   supports   the   following   kinds   of   alarms:   

 

NO_ZERO_CONSUMPTION

   -­‐   alarm   for   non   zero   consumption.   The   non   zero   consumption   is   defined   

as   condition   in   which   the   logger   is   detecting   consumption   over   certain   threshold   over   certain   long   
period   of   time.   For   example   the   logger   has   detected   a   NON   zero   consumption   over   6   consequitive   
hours.   

 

HIGH_CONSUMPTION

   -­‐   alarm   indicating   consumption   higher   than   a   certain   preconfigured   level   over   

certain   period   of   time.   For   example   1m

3

   over   1   hour.      

 

MISSED_TRANSMISSION

   -­‐   alarm   indicating   that   the   transmission   from   the   logger   did   not   happen.      

Содержание LPMDL-1101

Страница 1: ...are in proximity distance you can meter with a single device gas power and heating Analog sensors metering LPMDL 1101 has two extra inputs for connecting analog sensors with 4 20 mA output An example...

Страница 2: ...yer GPRS Class 12 Dust Water protection IP68 Battery power 4 5 V 3xAA alcaline batteries Table I Technical specification 3 Functional specification Pulse metering the logger supports pulses generated...

Страница 3: ...e point of view nonauthorized modifications or additions are not authorized Terms of use The data logger is intended for use in the following environmental conditions for use indoors or outdoors witho...

Страница 4: ...peratures not lower than 20 C and not higher than 60 C in the original package Transportation is allowed to happen accidentally at temperatures below 20 C but not more than 8 hours Protect against sho...

Страница 5: ...Visit us at www thingslog com 359 875 32 80 70 sales thingslog com 5 Physical instalation Figure 1 Logger outlook and dimensions...

Страница 6: ...gh which it can be attached to a firm surface In order to attach the logger you will need a wall with stiff flat surface close to the meter or the sensor which you would like to measure Mark and drill...

Страница 7: ...Visit us at www thingslog com 359 875 32 80 70 sales thingslog com Figure 3 Logger input output ports Figure 4 LPMDL 1101 wiring scheme...

Страница 8: ...ry monitoring capabilities The batteries have to be replaced if the voltage level is under 20 3 8 V Figure 6 On the left logger without batteries on the right logger with batteries In order to replace...

Страница 9: ...owrd 4 Scann the QR code on the logger label Figure 7 Area to be scanned 5 If the scan is sucessfull the android app will be able to register your logger to your profile Note that you can register onc...

Страница 10: ...ration ThingsLog LPMDL 1101 1 Connect your logger to your meters and sensors as described in section physical instalaltion 2 Navigate to meny All Devices and pick your newly added logger Figure 8 Menu...

Страница 11: ...ord period Could be Minute Hour or Day This is the period on which the logger will log in memory the reading values from the pulse inputs or the period on which it will perform low power reading of it...

Страница 12: ...so you will be able to see the following message on your screen Figure 10 Confirmation of successful configuration If the configuration process is unsucessfull and the device stays in Not configured...

Страница 13: ...thingslog com 359 875 32 80 70 sales thingslog com Figure 11 Readings 8 4 2 Flow graph Flow menu allows the user to visualize the consumption flow of the meter captured by the logger Figure 12 Flow c...

Страница 14: ...onsumption graph 8 4 4 Data export The system supports readings data export from a a certain time range in CSV file format Figure 14 Data export in CSV file format 8 5 Normal operation dashboard After...

Страница 15: ...fined as condition in which the logger is detecting consumption over certain threshold over certain long period of time For example the logger has detected a NON zero consumption over 6 consequitive h...

Страница 16: ...lower than the expected one ALL_ZERO_CONSUMPTION alarm signaling zero consumption throught certain time period For there is no consumption for 24 hours Could potentially indicate a fault meter DEVICE...