© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021690/10/20/short
Phone +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·
Page 15 of 16
Temperature range Operating temperature -50 ... +80°C
Storage temperature -55 ... +80°C
Operating voltage
Supply without
cover heating
6 ... 40V DC or 10 ... 28V AC 50Hz / 60Hz
typ. 50mA @ 24V
Operating voltage
Supply with cover
heating
24V AC/DC
±
15%, 25VA typically @ 24V nominal
(execution only 4.9200.x0.xxx, 4.9202.x0.xxx)
Type of protection
IP 67 (when mounted correctly, see section 2.
Installation).
Housing
4.92xx.xx.xxx
Plastic: LEXAN (polycarbonate, UV-stabilised) impact
and weather-resistant.
Mounting
e.g. on mast tube outer-Ø 48 … 49mm, inner-Ø
>30mm
Type of connection 19 pin plug connection.
Weight
Approx. 900g (full version).
1),2), 3), 4), 5), 6),7)
;
8)
@ 4.9200.x0.00x
1), 2), 3), 7)
@ 4.9201.00.00x
1), 2), 4), 5), 7)
@ 4.9202.x0.xxx
1), 2), 7)
@ 4.9203.00.00x