Installation of the USB/RS485 Interface Converter 
9.1702.40.002 

 

For the installation of the USB/RS485 interface converter please proceed as follows: 

1.  Put the USB-plug of the RS485 converter into the provided socket of the PC. 

2.  The PC identifies a new instrument, and displays it as follows. 

3.  Select in the dialogue “No, not this time”. 

4.  Acknowledge the next dialogue with OK. 

5.  Windows will install the driver for the USB/RS485 converter. 

6.  After successful completion the instrument is ready for use. 

7.  In the Windows system control a new COM-port is registered. The program 

“ThiesDeviceUtility.EXE” is using this port automatically. 

8.  Settings for RS485 half-duplex operation. 

In half-duplex operation the connections 1,2, and 6 are used. The sliding switches 
have to be set as follows: 

1: ON   

3: OFF 

2: OFF  

4: OFF 

9.  Settings for RS485 full-duplex operation. 

In full-duplex operation the connections 1,2,3,4, and 6 are used. The sliding switches 
must be set as follows: 

1: ON   

3: ON 

2: OFF  

4: ON 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SENSOR US

Страница 1: ...R US Short manual 4 920x x0 xxx From Softwareversion V4 16 Stand 02 2020 4 9200 00 xxx 4 9201 00 x0x 4 9200 20 xxx 4 9202 00 00x 4 9203 00 x0x Dok No 021690 10 20 short T H E W O R L D O F W E A T H E...

Страница 2: ...cribed in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible...

Страница 3: ...e manual available for download on our homepage Please download the tool with following link Link https www thiesclima com de Download In section General the program Thies Device Utility is the progra...

Страница 4: ...aution The allen screws must be tightened to 2Nm Alignment to north For exact determination of the wind and Brightness direction the CLIMA SENSOR US must be installed aligned to north true north When...

Страница 5: ...pter 3 page 7 16pole 2 Full duplex Chapter 3 page 7 8pole 0 Half duplex Chapter 5 page 9 8pole 1 Full duplex Chapter 4 page 8 8pole 2 Full duplex Chapter 4 page 8 Table 1 Selection Connection Diagram...

Страница 6: ...he button Terminal a window is opened where individual commands can be sent and parameters can be changed See also the online help of the program Thies Device Utility exe The program supports both the...

Страница 7: ...tra e 76 37083 G ttingen Germany 021690 10 20 short Phone 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 7 of 16 3 Connection Diagram of 4 920x x0 xxx in Full duplex Mo...

Страница 8: ...tra e 76 37083 G ttingen Germany 021690 10 20 short Phone 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 8 of 16 4 Connection Diagram of 4 920x x0 xxx in Full duplex Mo...

Страница 9: ...stra e 76 37083 G ttingen Germany 021690 10 20 short Phone 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 9 of 16 5 Connection Cable of 4 920x x0 xxx in Half duplex Mod...

Страница 10: ...ct in the dialogue No not this time 4 Acknowledge the next dialogue with OK 5 Windows will install the driver for the USB RS485 converter 6 After successful completion the instrument is ready for use...

Страница 11: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021690 10 20 short Phone 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 11 of 16 7 Dimensional Drawing...

Страница 12: ...asurement of air temperature It serves exclusively for the verification of the acquired wind measuring values Resolution 0 1K Air temperature 3 Measuring range 50 80 C Accuracy 0 3K 25 C 0 5K 45 60 C...

Страница 13: ...eter Absolute Humidity 3 Measuring Range Resolution 0 10 00g m 0 01g m Dew point temperature 3 Measuring range Accuracy Resolution Data see Air Temperature Windchill temperature 3 Remark measuring val...

Страница 14: ...n on voltage output 2000 Output Instantaneous values sliding means from 100msec to 2min in increments of 100msec freely selectable Output rate Update rate 10msec Resolution 16bit Parameter 4 9200 x0 x...

Страница 15: ...typ 50mA 24V Operating voltage Supply with cover heating 24V AC DC 15 25VA typically 24V nominal execution only 4 9200 x0 xxx 4 9202 x0 xxx Type of protection IP 67 when mounted correctly see section...

Страница 16: ...79001 65 info thiesclima com www thiesclima com Page 16 of 16 Please contact us for your system requirements We advise you gladly ADOLF THIES GMBH CO KG Meteorology and environmental metrology Haupts...

Отзывы: