Thies CLIMA 5.4103.1 Series Скачать руководство пользователя страница 18

 

 

 

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany    

 

 

021197/07/19 

Tel. +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·

www.thiesclima.com

  

 

Seite 18 von 20 

11 EC-Declaration of Conformity 

 

 

 

Document-No.:  000902 

Month:  07  Year:  19 

 

Manufacturer: 

A D O L F   T H I E S   G m b H   &   C o.  K G

 

Hauptstr. 76 
D-37083 Göttingen        
Tel.: (0551) 79001-0  
Fax: (0551) 79001-65      
email: 

[email protected]

 

 

This declaration of conformity is issued under the sole responsibility of the manufacturer 
 

Description of Product: 

Precipitation Transmitter 

 

Article No. 

5.4103.10.000 

5.4103.10.012 

5.4103.10.112 

5.4103.10.700 

 

5.4103.11.000 

5.4103.20.041 

5.4103.20.641 

5.4103.20.741 

 

5.4103.21.021 

5.4103.30.000 

5.4103.30.700

 

5.4103.31.000 

 

5.4103.32.000 

 

 

 

  

 

 

 

 

 

  

  

  

 

specified technical data in the document: 
 

021196/05/19; 021334/01/19; 021469/11/09; 021704/07/12 
021767/11/14; 021775/08/14; 021831/03/18; 021833/03/18 

 

The indicated products correspond to the essential requirement of the following European Directives and Regulations: 

 
 

2014/30/EU 

DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 
on the harmonisation of the laws of the Member States relating to electromagnetic compatibility 
 

2014/35/EU 

DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 
on the harmonisation of the laws of the Member States relating to the making available on the market of electrical 
equipment designed for use within certain voltage limits 

 
552/2004/EC 

 

Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004  

on the interoperability of the European Air Traffic Management network  (the interoperability Regulation) 

 
2011/65/EU 

DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL  

of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical  and electronic equipment 
 

2012/19/EU 

DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

 

 

of 4 July 2012 on waste electrical and electronic equipment (WEEE) 

 
 
The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards: 

 

EN 61000-6-2 

Electromagnetic compatibility 
Immunity for industrial environment 

 

 

EN 61000-6-3 

Electromagnetic compatibility 
Emission standard for residential, commercial and light industrial environments 

 

 

EN 61010-1 

Safety requirements for electrical equipment for measurement, control, and  laboratory use.      
Part 1: General requirements 

 

EN 50581 

Technical documentation for the assessment of electrical and electronic products with respect to the restriction 
of hazardous substances 

 
 
Place:  Göttingen                                                                         Date:  02.07.2019

     

Signed for and on behalf of: 
 

 

 

This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. 
Please pay attention to the security advises of the provided instructions for use.

 

 

 

 

Содержание 5.4103.1 Series

Страница 1: ...Precipitation Monitor Instruction for use 5 4103 1x xxx 5 4103 31 000 Dok No 021197 07 19 T H E W O R L D O F W E A T H E R D A T A...

Страница 2: ...e product is designed for a specific application as described in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by...

Страница 3: ...itation Sensor with Cable Gland 7 4 2 1 Connector for Precipitation Monitor with factory connected Cable 7 4 2 2 Connector for Precipitation Monitor without factory connected Cable 8 4 2 3 Electrical...

Страница 4: ...for external ON OFF heating control 5 4103 11 000 Precipitation status Relay Optocouplers 12 28V AC DC yes mode A Terminal strip and cable gland 5 4103 31 000 Precipitation status Relay Optocouplers...

Страница 5: ...occur even within a clearly shorter time than 50sec End of Precipitation The reset of the relay i e the end of the precipitation period occurs when no more raindrops hail stones etc are detected afte...

Страница 6: ...ntact W R closed Precipitation yes is signalized with missing or interrupted operating voltage sensor off thus device protection is existing even in this status 3 2 Definition to the Precipitation Eve...

Страница 7: ...nt while operating is not exposed to strong vibrations or shocks The pictured tube is not included in delivery 5 4103 11 000 The operating position of the precipitation monitor is horizontal The holdi...

Страница 8: ...the upper part again and screw it evenly and tightly to the bottom Attetion Make sure that the contact pins are not deformed when putting on the cover The fixing screws for the cover must be srewed d...

Страница 9: ...Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 9 von 20 4 2 4 Connection Diagramm Note The cable shield must only be placed on the side of th...

Страница 10: ...551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 10 von 20 1 2 3 4 5 6 7 Article No 5 4103 10 700 Polbild mit Sicht auf L tanschluss des Gegenstecker Article No 5 4103 10 1...

Страница 11: ...elay output is undefined after switching on the operating voltage and shows no precipitation 6 Maintenance The device is maintenance free Cleaning The pollution and the pollution level is dependent on...

Страница 12: ...due to special ambient conditions this can be done by means of switches DIP1 and DIP2 DIP1 Switch off delay for the end of precipitation period DIP2 Drop event filter for the start of precipitation p...

Страница 13: ...F ON ON 12 ON OFF ON ON 325 ON OFF ON ON 13 OFF ON ON ON 350 OFF ON ON ON 14 ON ON ON ON 375 ON ON ON ON 15 Grey marked squares factory settings DIP switch adjustment OFF OFF OFF OFF not defined 7 3 D...

Страница 14: ...pitation yes relay contract W R closed Precipitation no relay contract W A closed Power failure Sensor off relay contract W R closed Switch on condition 1 15 incidences within 50sec settable Switch of...

Страница 15: ...fo thiesclima com www thiesclima com Seite 15 von 20 Heating Control temperature Hysteresis Power Two level controller approx 8 C 0 1K Max 0 5A 12V max 1A 25V Ambient temperature 30 60 C Protection IP...

Страница 16: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 16 von 20 5 4103 10 700 5 4103 11 000...

Страница 17: ...Accessories Optional Power Supply Unit 9 3388 00 002 The power supply unit serves for the current supply of the precipitation monitor order no 5 4103 10 000 It supplies the necessary operation voltage...

Страница 18: ...to the making available on the market of electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 Mar...

Страница 19: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 19 von 20...

Страница 20: ...001 65 info thiesclima com www thiesclima com Seite 20 von 20 Sprechen Sie mit uns ber Ihre Systemanforderungen Wir beraten Sie gern ADOLF THIES GMBH CO KG Meteorologie und Umweltmesstechnik Hauptstra...

Отзывы: