7.4  Setting of the Heating Mode 

Heating mode is factory-set. 

If the factory-setting has to be changed due to special ambient conditions this can be done 
by means of solder bridges. This procedure should be carried out by the manufacturer.  

 

8  Technical Data 

Measuring values 

 

 

Precipitation status „yes / no“ via relay. 

 

Particle event as pulse via optocoupler. 

Measuring system / 
Sensor 

Optical, light-barrier. 

Sensor area  : 25cm

2

Drop size  : 

 0,2mm. 

 

 

Output 1 

 

Switch output relay 

Precipitation „yes“ 

 

=  relay-contract W + R closed.  

Precipitation „no“ 

 

=  relay-contract W + A closed.  

Power failure (Sensor „off“)  =  relay-contract W + R closed.  

Switch-on condition 

1... 15 incidences within 50sec. (settable). 

Switch-off delay 
5.4103.10.xxx 
5.4103.31.000 

 
25 ... 375sec. 
2,5…187.5sec. 
See „Adjusting incidences and switch-off delay“. 

 

 

Output 2 

 

Signal output optocoupler 

Output rate 

Precipitation particles trigger signal pulse. 

Max. 15pulse/s

 

Switch-on condition 

1 event. 

Switch-off delay 

None. 

 

 

General 

 

Specification relay 

Contact loading (relay) 

Attention: 

with model 
5.4103.10.700 

 
230V AC; 4A. 
 
Max. 60V AC; 4A. 

Specification optocoupler  

Output 

Pulse output 

Pulse duration 

 
Photo transistor, galvanically isolated, 

C=+ Pot., E=- Pot. 

Umax.= 32V   Imax.= 5mA. 
60msec. 

Operating voltage 

12V … 28V AC/DC. 

Operation current 
 

Ca.   50mA @  no precipitation, heating off. 
Ca.   30mA @  no precipitation, heating off. 

 

 

 

Содержание 5.4103.1 Series

Страница 1: ...Precipitation Monitor Instruction for use 5 4103 1x xxx 5 4103 31 000 Dok No 021197 07 19 T H E W O R L D O F W E A T H E R D A T A...

Страница 2: ...e product is designed for a specific application as described in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by...

Страница 3: ...itation Sensor with Cable Gland 7 4 2 1 Connector for Precipitation Monitor with factory connected Cable 7 4 2 2 Connector for Precipitation Monitor without factory connected Cable 8 4 2 3 Electrical...

Страница 4: ...for external ON OFF heating control 5 4103 11 000 Precipitation status Relay Optocouplers 12 28V AC DC yes mode A Terminal strip and cable gland 5 4103 31 000 Precipitation status Relay Optocouplers...

Страница 5: ...occur even within a clearly shorter time than 50sec End of Precipitation The reset of the relay i e the end of the precipitation period occurs when no more raindrops hail stones etc are detected afte...

Страница 6: ...ntact W R closed Precipitation yes is signalized with missing or interrupted operating voltage sensor off thus device protection is existing even in this status 3 2 Definition to the Precipitation Eve...

Страница 7: ...nt while operating is not exposed to strong vibrations or shocks The pictured tube is not included in delivery 5 4103 11 000 The operating position of the precipitation monitor is horizontal The holdi...

Страница 8: ...the upper part again and screw it evenly and tightly to the bottom Attetion Make sure that the contact pins are not deformed when putting on the cover The fixing screws for the cover must be srewed d...

Страница 9: ...Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 9 von 20 4 2 4 Connection Diagramm Note The cable shield must only be placed on the side of th...

Страница 10: ...551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 10 von 20 1 2 3 4 5 6 7 Article No 5 4103 10 700 Polbild mit Sicht auf L tanschluss des Gegenstecker Article No 5 4103 10 1...

Страница 11: ...elay output is undefined after switching on the operating voltage and shows no precipitation 6 Maintenance The device is maintenance free Cleaning The pollution and the pollution level is dependent on...

Страница 12: ...due to special ambient conditions this can be done by means of switches DIP1 and DIP2 DIP1 Switch off delay for the end of precipitation period DIP2 Drop event filter for the start of precipitation p...

Страница 13: ...F ON ON 12 ON OFF ON ON 325 ON OFF ON ON 13 OFF ON ON ON 350 OFF ON ON ON 14 ON ON ON ON 375 ON ON ON ON 15 Grey marked squares factory settings DIP switch adjustment OFF OFF OFF OFF not defined 7 3 D...

Страница 14: ...pitation yes relay contract W R closed Precipitation no relay contract W A closed Power failure Sensor off relay contract W R closed Switch on condition 1 15 incidences within 50sec settable Switch of...

Страница 15: ...fo thiesclima com www thiesclima com Seite 15 von 20 Heating Control temperature Hysteresis Power Two level controller approx 8 C 0 1K Max 0 5A 12V max 1A 25V Ambient temperature 30 60 C Protection IP...

Страница 16: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 16 von 20 5 4103 10 700 5 4103 11 000...

Страница 17: ...Accessories Optional Power Supply Unit 9 3388 00 002 The power supply unit serves for the current supply of the precipitation monitor order no 5 4103 10 000 It supplies the necessary operation voltage...

Страница 18: ...to the making available on the market of electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 Mar...

Страница 19: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 19 von 20...

Страница 20: ...001 65 info thiesclima com www thiesclima com Seite 20 von 20 Sprechen Sie mit uns ber Ihre Systemanforderungen Wir beraten Sie gern ADOLF THIES GMBH CO KG Meteorologie und Umweltmesstechnik Hauptstra...

Отзывы: