Thies CLIMA 4.3515.5 Series Скачать руководство пользователя страница 4

 

4 - 10 

021150/02/12

 

 

1 Models 

available 

Order-No. 

Meas. range 

Output 

Heating 

Connection 

Housing-

colour 

4.3515.50.000 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

24V 

3 m cable LiYY 4 x 0.25 mm² 

white 

4.3515.50.100 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

24V 

3 m cable LiYY 4 x 0.25 mm² 

black 

4.3515.50.109 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

12V 

3 m cable LiYY 4 x 0.25 mm² 

black 

4.3515.51.000 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

w/o 

3 m cable LiYY 2 x 0.5 mm² 

white 

4.3515.51.100 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

w/o 

3 m cable LiYY 2 x 0.5 mm² 

black 

4.3515.51.110 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

w/o 

10 m cable LiYY 2 x 0,5 mm² 

black 

4.3515.60.115 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

24V 

15 m cable Li9YC22Y  
4 x 0.55 mm², UV-resistant 

black 

4.3515.61.100 <0.9...40 

m/s

 

100Hz @ 40m/s 
(typ. 2,5Hz / ms

-1

)

 

w/o 

3 m cable LiYY 2 x 0.22 mm², 
UV-resistant 

black 

2 Application 

The small wind transmitter is designed for the acquisition of the horizontal wind velocity. The 
measuring value is output as frequency, which is proportional to the wind speed. The measuring 
data available are ideally adapted to the supply in display instruments, recording instruments, 
datalogger, as well as process control systems. 

For trouble-free winter operation the instrument is optionally equipped with a heating (PTC-heating 
element). 

3  Construction and Mode of Operation 

The outer parts of the instrument are made of plastic, the mounting angle is made of stainless steel. 
Labyrinth gaskets protect the parts inside the instrument against precipitation. 

The cup star is set into rotation by the wind. An axis, running in friction bearings, is fixed at the cup 
star, and leads two magnets through a Reed-contact. The pulses thus produced are available as 
output signals. 

4  Recommendation Side Selection/Standard Installation 

In general wind measurement instruments should be able to detect the wind conditions of a large 
area. In order to obtain comparable values when determining the surface wind, measurements 
should be taken at a height of 10 meters over an even unobstructed area. An unobstructed area 
means that the distance between the wind transmitter and an obstacle should be at least 10 times 
the height of the obstacle (s. VDI 3786). If it is not possible to fulfil this condition, then the wind 

 

Содержание 4.3515.5 Series

Страница 1: ...ATHER DATA Instruction for Use 021150 02 12 Small Wind Transmitter 4 3515 5x xxx 4 3515 6x xxx ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 49 551...

Страница 2: ...ns The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device p...

Страница 3: ...Side Selection Standard Installation 4 5 Installation 5 5 1 Mechanical Mounting 5 5 2 Electrical Mounting 5 6 Connecting Diagram 6 7 Maintenance 6 8 Technical Data 6 9 Dimension diagram 7 10 EC Decla...

Страница 4: ...speed The measuring data available are ideally adapted to the supply in display instruments recording instruments datalogger as well as process control systems For trouble free winter operation the in...

Страница 5: ...by turbulences into consideration Attention Storing mounting and operation under weather conditions is permissible only in vertical position as otherwise water can get into the instrument 5 1 Mechanic...

Страница 6: ...100 Measuring range 0 9 40 m s Electrical output 100Hz 40m s typ 2 5Hz ms 1 Resolution 0 4 m wind run Accuracy 0 5 m s or 5 of measuring value Measuring system 1 x Reed contact 2 x magnet Contact Ree...

Страница 7: ...9 Dimension diagram 7 10 021150 02 12...

Страница 8: ...the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC 2006 95 EC DIRECTIVE 2006 95 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December...

Страница 9: ...9 10 021150 02 12...

Страница 10: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 10 10 02115...