Thies CLIMA 4.3515.5 Series Скачать руководство пользователя страница 2

 

Safety Instructions

• 

Before operating with or at the device/product, read through the operating instructions. 
This manual contains instructions which should be followed on mounting, start-up, and operation.  
A non-observance might cause: 
 

 

- failure of important functions 

 

 

- Endangering of persons by electrical or mechanic effect 

 

 

- Damages at objects 

• 

Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician 
who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. 

• 

Repairs and maintenance may only be carried out by trained staff or 

Adolf Thies GmbH & Co. KG

. Only 

components and spare parts supplied and/or recommended by 

Adolf Thies GmbH & Co. KG

 should be used for 

repairs.  

• 

Electrical devices/products must be mounted and wired only in voltage-free state. 

• 

Adolf Thies GmbH & Co KG

 guarantees proper functioning of the device/products provided that no 

modifications have been made to the mechanics, electronics or software, and that the following points are 
observed: 

• 

All information, warnings and instructions for use included in these operating instructions must be taken into 
account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring 
system / device / product.  

• 

The device / product is designed for a specific application as described in these operating instructions. 

• 

The device / product should be operated with the accessories and consumables supplied and/or recommended 
by 

Adolf Thies GmbH & Co KG

 . 

• 

Recommendation: As it is possible that each measuring system / device / product under certain conditions, and 
in rare cases, may also output erroneous measuring values, it is recommended to use redundant systems with 
plausibility checks with 

security-relevant applications

Environment 

• 

As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the 
objectives of environmental protection and is therefore willing to take back all supplied products 
governed by the provisions of "

ElektroG

(

German Electrical and Electronic Equipment Act) 

and to perform environmentally compatible disposal and recycling. We are prepared to take 
back all Thies products concerned free of charge if returned to Thies by our customers 
carriage-paid. 

 

• 

Make sure you retain packaging for storage or transport of products. Should packaging 
however no longer be required, arrange for recycling as the packaging materials are designed 
to be recycled. 

 

Documentation 

• 

©  Copyright 

Adolf Thies GmbH & Co KG

, Göttingen / Germany 

• 

Although this operating instruction has been drawn up with due care, 

Adolf Thies GmbH & Co KG

 can accept 

no liability whatsoever for any technical and typographical errors or omissions in this document that might 
remain. 

• 

We can accept no liability whatsoever for any losses arising from the information contained in this document. 

• 

Subject to modification in terms of content. 

• 

The device / product should not be passed on without the/these operating instructions. 

 

 

2 - 10 

021150/02/12

 

 

Содержание 4.3515.5 Series

Страница 1: ...ATHER DATA Instruction for Use 021150 02 12 Small Wind Transmitter 4 3515 5x xxx 4 3515 6x xxx ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 49 551...

Страница 2: ...ns The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device p...

Страница 3: ...Side Selection Standard Installation 4 5 Installation 5 5 1 Mechanical Mounting 5 5 2 Electrical Mounting 5 6 Connecting Diagram 6 7 Maintenance 6 8 Technical Data 6 9 Dimension diagram 7 10 EC Decla...

Страница 4: ...speed The measuring data available are ideally adapted to the supply in display instruments recording instruments datalogger as well as process control systems For trouble free winter operation the in...

Страница 5: ...by turbulences into consideration Attention Storing mounting and operation under weather conditions is permissible only in vertical position as otherwise water can get into the instrument 5 1 Mechanic...

Страница 6: ...100 Measuring range 0 9 40 m s Electrical output 100Hz 40m s typ 2 5Hz ms 1 Resolution 0 4 m wind run Accuracy 0 5 m s or 5 of measuring value Measuring system 1 x Reed contact 2 x magnet Contact Ree...

Страница 7: ...9 Dimension diagram 7 10 021150 02 12...

Страница 8: ...the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC 2006 95 EC DIRECTIVE 2006 95 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December...

Страница 9: ...9 10 021150 02 12...

Страница 10: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 10 10 02115...

Отзывы: