Streamfeeder Reliant 3700
Universal Friction Feeder
Product Guide
Feature
Description
AC power cordset connector
Cordset plugs into this IEC320 connector to provide feeder with power
from a grounded/fused outlet. Switchable for either 115- or 230-VAC.
Feed/flight trigger connector
The remote flight-detect sensor plugs into this 4-pin connector to provide
the “start” signal to begin a feed cycle.
Power On/Off
Toggles AC power On or Off.
Fuse holder
Contains two replaceable GMD3, 3-Amp, 5-mm fuses.
IMPORTANT:
Always make sure power module is replaced exactly as removed. Failure
to follow this caution can result in damaged electrical parts.
Reset button/fault indicator
Labeled
Reset
, the primary purpose of this pushbutton switch/indicator is
to reset the feeder after: 1) a “time-out” occurs or, 2) the discharge safety
shield is opened or, 3) "miss-feed" occurs. Time-outs occur: 1) during a
misfeed or, 2) when the hopper runs out of material; or 3)
flashing during
"miss" condition. Built-in indicator illuminates: 1)
steady during a time-out
condition; 2)
flashing during an “open” discharge safety shield.
Variable speed control
This dial switch (labeled
Speed
) allows the feeder speed to be
synchronized with an inserter, or infeed conveyor. Turning counter-
clockwise decreases speed; clockwise increases speed.
Cycle button
This pushbutton switch (labeled
Cycle
) is primarily used during
preparation and test, this is used to manually start (or run) a feeder cycle.
To “start” a cycle, push
Cycle
completely in and then release.
Batch count thumbwheels (optional)
Note: Batch count feeders only. These two wheels allow you to select a
number from 1 to 99 to which the feeder will always count and then stop.
Fault ouput connector (not shown)
The fault output I/O cable plugs into this connector to provide the host
system interface.
Fault configuration selector switch
This switch allows the operator to select between stopping the feeder
(not shown)
or sounding an alarm only when a fault is detected.
Table 1-2.
Control Panel Feature Descriptions
Содержание Streamfeeder Reliant 3700
Страница 1: ...Product Guide Reliant 3700...
Страница 30: ...18 Streamfeeder Reliant 3700 Universal Friction Feeder Product Guide Notes...
Страница 44: ...32 Streamfeeder Reliant 3700 Universal Friction Feeder Product Guide Notes...
Страница 49: ...Streamfeeder Reliant 3700 Universal Friction Feeders 37 Product Guide 7 Mechanical Components...
Страница 51: ...Streamfeeder Reliant 3700 Universal Friction Feeders 39 Product Guide...
Страница 53: ...Streamfeeder Reliant 3700 Universal Friction Feeders 41 Product Guide...
Страница 55: ...Streamfeeder Reliant 3700 Universal Friction Feeders 43 Product Guide...
Страница 61: ...Streamfeeder Reliant 3700 Universal Friction Feeders 49 Product Guide...
Страница 65: ...Streamfeeder Reliant 3700 Universal Friction Feeders 53 Product Guide...
Страница 67: ...Streamfeeder Reliant 3700 Universal Friction Feeders 55 Product Guide...
Страница 69: ...Streamfeeder Reliant 3700 Universal Friction Feeders 57 Product Guide...
Страница 78: ...66 Streamfeeder Reliant 3700 Universal Friction Feeders Product Guide Reliant Series CPU Board...
Страница 82: ...70 Streamfeeder Reliant 3700 Universal Friction Feeders Product Guide Notes...
Страница 93: ......
Страница 94: ...2007 Thiele Technologies Inc Streamfeeder Printed in the USA...