CONTENTS   

 

 

 

 

 

 

 

 

 

 

 

 
User’s Section 
Specification 

 

 

………………………………………………… 

Introduction  

 

 

………………………………………………… 

Operating the Fire   

 

………………………………………………… 

8 - 9 

 
Installation and Servicing 
Installation Dimensions   

………………………………………………… 

2 - 5 

Specification 

 

 

………………………………………………… 

Installation Instructions   

………………………………………………… 

10 - 13 

Maintenance & Servicing  

………………………………………………… 

14 

 
 
SPECIFICATION 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

IMPORTANT 
 

  THIS APPLIANCE IS SUITABLE FOR USE WITH EITHER LIQUIFIED 

PETROLEUM GAS (LPG) OR NATURAL GAS AS SPECIFIED AND SHOULD 
NOT BE USED ON ANY OTHER GAS 

 

   USE ONLY THE GAS PRESSURES SPECIFIED ABOVE  

 

 

Model 

Range 

FI20000 

FI20000NG 

FI21000 

FI22000 

FI22000NG 

FI23000 

FI23000NG 

Model 

Name 

SOLARIS 

SOLARIS 

SOLARIS 

MAGNA 

MAGNA 

SOLARIS LS  SOLARIS LS 

GAS TYPE 

LPG 

NATURAL 

GAS 

LPG 

LPG 

NATURAL 

GAS 

LPG 

NATURAL 

GAS 

Size, mm 

H  x  W  x  D 

H  x  W  x  D 

H  x  W  x  D 

H  x  W  x  D 

H  x  W  x  D 

H  x  W  x  D 

H  x  W  x  D 

Fire Front 

574X614X75  574X614X75  574X614X131  639X621X75  639X621X75  574X758X60  574X758X60 

Rear Box  509X484X141  509X484X141  509X484X141  509X484X141  509X484X141  509X484X141  509X484X141 

Fire 

Opening 

Min 538 x 540 

Max 570 x 540 

Min 538 x 540 

Max 570 x 540 

Min 538 x 540 

Max 570 x 540 

Min 538 x 540 

Max 570 x 540 

Min 538 x 540 

Max 570 x 540 

Min 538 x 540 

Max 570 x 540 

Min 538 x 540 

Max 570 x 540 

Total Input 

3.8kW 

3.8kW 

3.8kW 

3.8kW 

3.8kW 

3.8kW 

3.8kW 

Injector 

Size 

Sabaf 1.0mm  Sabaf 1.4mm  Sabaf 1.0mm  Sabaf 1.0mm  Sabaf 1.4mm  Sabaf 1.0mm  Sabaf 1.4mm 

 Ignition 

Integral Piezo  Integral Piezo  Integral Piezo  Integral Piezo  Integral Piezo  Integral Piezo  Integral Piezo 

Voltage 

N/A 

N/A 

230V ~ 50Hz 

N/A 

N/A 

N/A 

N/A 

Nox Rating (Highest Butane) :-  192.37 mg/kWh   All Models 

 

Gas Category 
 

CAT I

3

+ (28-30/37) 

 

CAT I

3

 B/P (30) 

 

 

CAT I

H (20) 

BUTANE (G30) 28-30 mbar 

BUTANE (G30) 30 mbar   

NATURAL 

PROPANE (G31) 37 mbar 

PROPANE (G31) 30 mbar  

GAS (G20) 20 mbar 

 

Содержание SPINFLO FI 20000

Страница 1: ...22000NG S FI 23000NG PCFI0110 Issue 8 USER AND INSTALLATION INSTRUCTIONS SPINFLO LIMITED Unit 19 Oakham Drive Parkwood Industrial Estate Rutland Road Sheffield S3 9QX ENGLAND TEL 44 0 114 273 8157 FAX...

Страница 2: ...2...

Страница 3: ...3...

Страница 4: ...4...

Страница 5: ...5...

Страница 6: ...Front 574X614X75 574X614X75 574X614X131 639X621X75 639X621X75 574X758X60 574X758X60 Rear Box 509X484X141 509X484X141 509X484X141 509X484X141 509X484X141 509X484X141 509X484X141 Fire Opening Min 538 x...

Страница 7: ...ilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor fan Prolonged intensive use of the appliance may call for additional ventilation for example...

Страница 8: ...conds then release OPERATION Light the fire follow ignition sequence above After ignition the setting of the fire is on LOW See Fig 2 Control Positions To adjust to HIGH setting rotate the knob fully...

Страница 9: ...e appliance serviced at least once a year DO check periodically that the air vents and flue are clear from obstructions DO NOT allow children near the fire when in use DO NOT use abrasive cleaners or...

Страница 10: ...liance is suitable for installation into Holiday Homes only In all cases the national standards with regard to ventilation for the particular vehicle into which the appliance is to be installed must b...

Страница 11: ...air vents are not inadvertently blocked or shut off FIXINGS The aperture for the appliance is 570mm high by 540mm wide and the appliance is fixed as shown in fig 3 The flue pipe must be fixed to the...

Страница 12: ...on functions correctly and the pilot remains lit see page 3 Turn to high rate check function correct see page 4 Turn off check flame extinguished and knob position correct see page 5 Test For Spillage...

Страница 13: ...ce should be sought from the supplier If an extractor fan is fitted in the same or adjacent room as the fire then the test should be carried out with the fan switched on FINAL CHECKS 1 Ensure all remo...

Страница 14: ...r pipe pilot pipe and thermocouple and remove from the control Disconnect spark ignition lead from spark electrode by pulling Unscrew locknut from mounting bracket and remove control 5 Burner replacem...

Отзывы: