MAINTENANCE & SERVICING
This appliance needs little maintenance other than cleaning. All parts should be cleaned
using either a duster or a damp cloth. Do not use abrasive cleaners, steel wool or cleansing
powders. The control knob is a push fit and can be removed for cleaning.
ALL SERVICING MUST BE CARRIED OUT BY AN APPROVED COMPETENT PERSON
AFTER EACH SERVICE THE APPLIANCE MUST BE CHECKED FOR GAS SOUNDNESS
1. Remove front cover from appliance
Remove the push fit control knob. Remove fixing screw located through slot in the
hood (fig. 4). Pull top of cover away from fire and lift off.
2. Change the lamp (Model FI21000 Only).
Unplug lamp unit before replacing the lamp
Remove front cover (1) and change the lamp.
3. Remove appliance from housing
Remove front cover (1). Disconnect gas supply. Remove four fixing screws from fixing
brackets (fig. 3). Pull fire out of opening until access to flue pipe is gained. Loosen
hose clamp and pull flue pipe away from fire.
4. Control replacement
Remove front cover (1). Disconnect gas supply. Unscrew burner pipe, pilot pipe and
thermocouple and remove from the control. Disconnect spark ignition lead from spark
electrode by pulling. Unscrew locknut from mounting bracket and remove control.
5. Burner replacement
Remove front cover (1). Disconnect gas supply. Unscrew the screw that attaches the
pilot assembly to the burner. Remove the locknut from the injector assembly.
Then remove the two screws, which attach the burner to the radiant housing. Remove
the burner.
6. Burner injector replacement
Remove front cover (1). Disconnect gas supply. Remove the locknut from the injector
assembly. Disconnect burner pipe from control tap and remove pipe/injector.
7. Thermocouple replacement
Remove front cover (1). Disconnect gas supply. Disconnect thermocouple from control
tap. Remove screw and retaining flange from pilot assembly. Remove thermocouple.
8. ODS / pilot replacement
Remove front cover (1). Disconnect gas supply. Disconnect pilot pipe from control tap.
Remove screw and retaining flange from pilot assembly. Remove ODS / pilot.
9. Radiant replacement
Remove front cover (1). Remove fixing screws shown in fig 7. Remove the radiant
retainer. Remove radiants.
IMPORTANT
•
AT LEAST ONCE EVERY 12 MONTHS THE FIRE, FLUE & TERMINAL
SHOULD BE CHECKED FOR CORRECT OPERATION.