![Thetford SOH1500 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/thetford/soh1500/soh1500_user-and-installation-instructions-manual_1106509007.webp)
7
INSTALLATION
Connection
Refer to the diagrams for its location. The appliance can be installed either fixed or
‘gimballed’ it is important to adhere to the instructions for the type of installation chosen.
Gimballed installation:-
A flexible hose must be used for connection to the gas supply and adhere to the
following requirements.
•
Use a hose certified to the standards/regulations in force.
•
A 8mm O/D inlet pipe is provided at the rear for gas supply
•
The hose length MUST not exceed 1.2m.
•
Hose is of adequate diameter for maximum gas consumption of appliance
•
Ensure the hose will not kink or squash when using the gimbal.
•
Ensure the hose is not likely to be damaged or cut.
•
The hose should not come into contact with hot surfaces.
Fixed installation:-
All fixed installations must be connected by copper tubing, a 8mm O/D inlet pipe
connection is provided at the rear.
If the flame on either the top burners or the grill show a tendency to lift, it is probable that
the line pressure is too great. Should there be excessive yellow tips (resulting in sooting)
then it is probable that the line pressure is too low and, in either case, the burners should
not be used until the line pressure has been checked.
This appliance is fitted with the following injectors:-
BURNERS 0.62mm (1.5kW)
GRILL 0.62mm (1.5kW)
OVEN
0.59mm (1.5kW)
The burners on this appliance have fixed aeration and no adjustment is necessary.
Depending on the gas being used, the burners should flame as follows:-
Propane - The flames should burn quietly with a blue/green colour with no sign
of yellow tips.
Butane - Normally on initial lighting, a small amount of yellow tipping will occur
and then slightly increases as the burner heats up.
IMPORTANT
•
After installation the appliance MUST be tested for soundness
•
Test ALL burners on high and low flame for flame stability.
•
The gas supply input pressure MUST not rise or fall significantly from
nominal when ALL appliances connected to the supply are operated
simultaneously. If NOT installed to the manufacturers instructions detailed
herein, we the manufacturer can not be held responsible for any problems
that occur, or poor performance that is perceived/witnessed.