background image

MAINTENANCE & SERVICING

 

 

Injector Sizes & Consumption Per Burner 

 

Model S~HB14000Z 

Burner 

            Injector orifice Consumption 

 

  Front 

 

LH 

 0.62 

or 

0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Front   RH         

0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Rear   LH 

          0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Rear   RH 

          0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 
Model S~HB14300Z 

Burner 

            Injector orifice Consumption 

 

 

 

Front   LH 

          0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Rear   LH            0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Centre RH 

          0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 
Model S~HB14500Z 

Burner 

            Injector orifice Consumption 

 

 

 

Front   LH 

          0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Rear   LH            0.62 or 0.67 mm 

5.4 or 5.9 MJ/hr 

 

 

 

Centre RH 

          0.81 mm 

 

9.0 MJ/hr 

 

A pressure test point is fitted to the gas manifold located below the control panel. The 
pressure is measured with the front left burner on high flame and with an inlet pressure of 
2.75 kPa  (Propane). 

 

Service Instructions 

ALL SERVICING MUST BE CARRIED OUT BY AN AUTHORISED PERSON 

 
1. Hob Burner Gas valve removal/replacement 

  Shut off gas supply and disconnect gas supply pipe from the unit. 

  Remove the hob from the bench top. 

  Remove the appropriate control knob by pulling up. 

  Unscrew the gas valve retaining nut. 

  From underside of hob, unscrew appropriate thermocouple nut at the gas valve. 

  Unscrew the appropriate gas supply pipe nut. 

  Remove the appropriate gas valve clamp by unscrewing the two screws. 

  Remove the gas valve. 

  Replace the tap and gasket. Refit using reverse procedure. 

 

2. Hob Burner Injector removal/replacement 

  Remove the pan support by pulling up to release it from the plastic clips.  

  Remove the appropriate burner cap and skirt. 

  With a 7mm A/F socket, unscrew injector from the bottom of the burner mixing tube. 

  Replace/refit using the reverse procedure. 

 
3. Thermocouple removal/replacement 

  Shut off gas supply and disconnect gas supply pipe from the unit. 

  Remove the hob from the bench top. 

  Remove the spring clip retaining the thermocouple at the burner. 

  From the underside of the hob, unscrew the appropriate thermocouple nut at the 

gas valve. 

  Remove the thermocouple. 

  Replace/refit using reverse procedure. 

 

9

Содержание S-HB14000Z

Страница 1: ...GAS FOR USE IN AUSTRALIA THETFORD AUSTRALIA PTY LTD 41 LARA WAY CAMPBELLFIELD VIC TEL 03 9358 0700 FAX 03 9357 7060 USER AND INSTALLATION INSTRUCTIONS WARNING This appliance must be installed by an a...

Страница 2: ...2 2...

Страница 3: ...CONTROL POSITIONS FIG 1 OFF FULL RATE LOW RATE MINIMUM ALLOWABLE DISTANCE TO COMBUSTIBLE MATERIAL FIG 2 OPTIONAL BATTERY POWERED SPARK IGNITION SERIESS HB14300 FIG 3 3...

Страница 4: ...4...

Страница 5: ...lation The use of a gas cooking appliance results in a production of heat and moisture in a room in which it is installed Ensure that the kitchen is well ventilated and in accordance with AG5601 Insta...

Страница 6: ...l units OR front right burner on left hand control units will accept 22cm pans On Models S HB14300Z S HB14500Z the single centre burner will accept 22cm pans Overloading the appliance will reduced per...

Страница 7: ...liance is suitable for use on Propane Gas Only 2 75 Kpa It is important that the regulator should be set to the correct pressure for the type of gas being used Excessive pressure must not be permitted...

Страница 8: ...UST NOT BE MODIFIED OR ADJUSTED UNLESS AUTHORISED AND CARRIED OUT BY THE MANUFACTURER OR HIS REPRESENTATIVE NO PARTS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER SHOULD BE USED ON THIS APPLIANCE Who...

Страница 9: ...as valve removal replacement Shut off gas supply and disconnect gas supply pipe from the unit Remove the hob from the bench top Remove the appropriate control knob by pulling up Unscrew the gas valve...

Отзывы: