background image

 

 

17 

6.2 

Securing the refrigerator 

 
1.

 

FIGURE 13

: If you use Thetford combustion seals, these need to be fixed in the way shown in the 

drawing to ensure optimum insulation. Fix the upper and lower flap of the combustion seal.  Fix the 
strips to the sides of the refrigerator in a vertical di rection at the rear of the refrigerator.  Fix the 
upper and lower flap of the combustion seal in the way shown in the drawing.   

 

FIGURE 14

: The refrigerator is installed in the unit using four screw holes  on the sides  (the N145 

models have got six  screw holes). 

 
1. 

Place the refrigerator completely straight in the unit (when the caravan or motor home is level, the 
refrigerator should also be level). 

2. 

Put screws through the holes on the inside of the refrigerator and screw it through the wall of the 
refrigerator into the unit.  

3. 

Place the white caps over the holes.  

 

If the size of the unit is such that the combustion seal fails to seal properly, use a different 
kind of sealing to keep hazardous combustion gases out of the living area of the caravan or 
motor home.  

 

6.3 

Technical drawings 

 
Technical drawings are available for every type of refrigerator. These are precise A1 (scale 1:5) drawings 
stating all relevant measurements of the refrigerator and its surrounding. If wished for, Thetford is able to 
send you the technical drawing of your refrigerator model.  

6.4 

Fitting the door panel  

 

FIGURE 15

: In order to fit the door panel, the refrigerator’s door needs to be demounted. [1] Open 

the door, unfasten the screw from the top hinge point with a screwd river and remove the screw.  [2] 
Hold the door at a slight angle and lift the door from the lower hinge pen.  
[3] Remove the 3 screws with which the lower cover is attached to the door.  
[4] Remove the cover and slide the panel into the holder.    
[5] Repeat steps [1] / [2] and [3] in reversed order.  

7.

 

ELECTRICAL COMPONENTS 

 

-

 

The electrical connections have to comply with EN 60335-1 

-

 

A qualified person must install the electrical connection.  

-

 

The electrical components must be in accordance with the latest technical regulations.  

-

 

Wiring must be installed so that wires cannot come into contact with hot or sharp parts.  

7.1 

Connecting to the mains (230 V) 

 

-  Connecting the 230v cable to a properly earthed power point will increase the safety 

aspect.   

-  Make sure the power point is in a position  that is easy to reach.    
- Position the 230v power lead in such a way that it cannot come into contact with hot or   

sharp parts.  

- The mains connection must be fitted with a 3 A fuse.  
-  In case of a damaged power lead with one of the SES models (Smart Energy Selection, 

see figure 1), this must be replaced with a Thetford power lead.  

7.2

 

Connecting to a DC power supply  (12 V) for all piezo and electric models (fig. 1) 

 
These models have two 12V connection points to prevent the battery  from being discharge d by the 
refrigerator when the engine is not running.    

13. 

15. 

14. 

ENG 

ENG 

Содержание N100

Страница 1: ...ation manual Instructions pour l installation Einbau anleitung Instrucciones de montaje Instrusioni per l installazione Monteringsanvisningar Prirocnik z navodili za uporabo Installatiehandleiding 12 2 N80 N90 N100 N109 N110 N112 N145 REFRIGERATOR Ref 0305 ...

Страница 2: ...Px x 821 x 525 x 543 97 91 11 3 3 340 30 Manual piëzo N100 Ex x 821 x 525 x 543 97 91 11 3 3 340 30 Electric N100 Ax x 821 x 525 x 543 97 91 11 3 3 340 29 5 Smart Energy Selection N109 Ex x 821 x 525 x 543 103 95 11 3 3 340 26 5 Electric N110 Px x 821 x525 x 603 103 95 11 3 0 340 30 5 Manual piëzo N110 Ex x 821 x 525 x 603 103 95 11 3 0 340 30 5 Electric N112 Px x 821 x 525 x 632 113 107 11 3 1 34...

Страница 3: ...3 3 5 4 FIGURES 2 ...

Страница 4: ...4 6 7 8 FIGURES ...

Страница 5: ...5 9 10 FIGURES FIGURES N145 ...

Страница 6: ...6 Model H W D Hst Dst N80 825 490 515 220 235 N90 825 529 515 220 235 N100 825 529 515 N109 825 529 515 N110 825 529 515 N112 825 529 568 220 235 N145A 1250 529 515 N145E 1305 529 515 11 12 FIGURES ...

Страница 7: ...7 13 14 15 16 FIGURES ...

Страница 8: ...8 17 FIGURES ...

Страница 9: ...9 18 FIGURES ...

Страница 10: ...10 19 FIGURES ...

Страница 11: ...11 20 FIGURES ...

Страница 12: ...ETY INSTRUCTIONS 13 3 DETERMINING WHERE TO IN STALL THE REFRIGERATOR 14 4 OUTSIDE VENTS 15 5 COMBUSTION GASES OUTLET 16 6 REFRIGERATION INSTALLATION 16 7 ELECTRICAL COMPONENTS 17 8 GAS CONNECTION INSTALLATION 19 9 WIRING DIAGRAMS 19 ENG ...

Страница 13: ...K DE IS NL SE FI NO G30 Butane G31 Propane EN 732 specifications for liquid gas appliances Absorption refrigerators FIGURE 1 Specifications of other refrigerator models A B C D E F G H I Model Measurements H x B x D mm depthincl door Grossvolume incl freezer L Net volume incl freezer L Volume freezer L Input kWh 24 h Input gr 24h Net weight kg Operation average energy use at a surrounding temperat...

Страница 14: ...rigerator and its extractor must be installed in a way that allows easy access for maintenance and repairs The installation and connections must satisfy the most recent technical regulations The refrigerator is designed for powering by liquid gas butane and propane 12V DC or 230VAC The performance of the refrigerator may be affected by adjacent heat sources such as an oven or stove Protect the ref...

Страница 15: ...as to stream outside instead of building up on the floor A grating is used for this matter with the N80 90 112 models The other models N100 109 110 145 have a grating which is situated above floor level and therefore need an extra hole in the floor with a diameter in conformity with local regulations but we advice a diameter of at least Ø40 mm FIGURE 7 The upper ventilation grating The installatio...

Страница 16: ...e outlet of the exhaust is in the position as shown in the drawing below It is important to always keep a distance of 5mm minimum from the vent The outlet of the exhaust tube has to be close to the bottom side of the vent When positioned correctly use the clamp to fix the exhaust tube to the flue of the refrigerator For refrigerator model N145 only You do not need to install a separate extractor T...

Страница 17: ...igerator model 6 4 Fitting the door panel FIGURE 15 In order to fit the door panel the refrigerator s door needs to be demounted 1 Open the door unfasten the screw from the top hinge point with a screwdriver and remove the screw 2 Hold the door at a slight angle and lift the door from the lower hinge pen 3 Remove the 3 screws with which the lower cover is attached to the door 4 Remove the cover an...

Страница 18: ...1 A fuse 7 3 Connecting to a DC power supply 12 V for all S ES models see figure 1 The description below applies to the installation in motor homes Please contact Thetford if you wish to install in any other vehicle The refrigerator is provided with a 3 wire 12v input cable red white black E powerless Engine signal to prevent 12v power supply from entering the heating device of the refrigerator wh...

Страница 19: ...are in any doubt Take notice of the maximum life of the hose and replace it on time subject to the limits specified by the manufacturer or local regulations If the lower ventilation grating is not at floor level or slightly lower make a hole in the floor at the rear end of the refrigerator see figure 7 If a leak occurs this hole will allow the gas to stream outside instead of building upon the flo...

Отзывы: