BOILER MOUNTING
INSTALLATION
10
3.4.
Mounting the burner
The burner is mounted on the flange provided on the door of the boiler. First install the insulation
cord and then fix the burner on the flange with the four screws provided, as shown on Fig 5. Pay
attention so that the burner furnace is correctly positioned in the fire chamber and the door
opens normally.
Fig 5.
Mounting the burner
The pellet silo must be positioned normally from the right side of the boiler, so that the door
opens easily. It must be positioned as close to the boiler as possible so that the feeder length
will be sufficient.
The pellet feeder must be inserted in the silo before you fill it with pellets. The feeder must be
positioned with inclination, optimum at 30-45
o
to the floor. The pellet feeder cannot be
positioned at angle more than 45
o
, nor vertically or horizontally! After positioning secure
it so that it doesn’t move. The connection between the pellet feeder and the burner is done by
a flexible hose. This hose must also have an inclination and be tightened so that it allows free
fall of the pellets towards the burner. The connection of the hose with the burner and the feeder
must be air-tight. Use the tighteners provided.
The positioning of the pellet feeder and the silo are very important to the
burner’s operation! If not positioned correctly it can cause malfunction and stop of the
burner.
Legend
1 Fixing screws
2 Sealing cord
3 Pellet burner