CONTENT:  

 

STANDARDS

—DIRECTIVES—SPECIFICATIONS

 

 

PREFACE

 

 

1. DESCRIPTION

 

 

2. DELIVERY /TRANSPORT

 

 

3. FEATURES OF THE BOILER MULTIPLEX

 

 

4. BOILER LOCATION

 

 

12 

5. CHIMNEY

 

 

14 

6. BOILER ASSEMBLING

 

 

16 

7. CONTROL PANEL 

 

 

16 

8. MAINTENANCE GENERAL INSTRUCTIONS  

 

18 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание MULTIPLEX MCL

Страница 1: ...MULTIPLEX MCL INSTRUCTION MANUAL ver 1 1...

Страница 2: ...tory The name THERMOSTAHL means GUARANTEE for the buyer THERMOSTAHL provides heating solutions for more than 20 years on the market The production experience and the expertise gives us the opportunity...

Страница 3: ...TIVES SPECIFICATIONS 3 PREFACE 4 1 DESCRIPTION 5 2 DELIVERY TRANSPORT 5 3 FEATURES OF THE BOILER MULTIPLEX 9 4 BOILER LOCATION 12 5 CHIMNEY 14 6 BOILER ASSEMBLING 16 7 CONTROL PANEL 16 8 MAINTENANCE G...

Страница 4: ...Electrical conections between burner and boiler Standard 763 Central heating boilers Minimum dimensions of the combustion chamber Standard 234 Central heating boilers Terminology nominal power techni...

Страница 5: ...Familiarize yourself with its operations and controls and follow strictly the instructions given If you have any questions or you need more information about particular points concerning the THERMOSTA...

Страница 6: ...is designed in such a way that all the surfaces that come in contact with the flame to be cooled by water including the grid where the ash and the remains of burning are The two ways of exhaust from t...

Страница 7: ...e the boiler during transport on the transport means so as not to slip Consider seriously that the gravity centre is above the geometric centre That means there is need of a special care during transp...

Страница 8: ...780 210 209 180 2 360 11 370 x 625 1150 600 0 37 900 230 233 200 2 420 13 5 370 x 625 1400 600 0 37 900 260 256 220 2 450 14 370 x 625 1400 600 0 37 900 290 291 250 3 620 17 370 x 625 1100 950 0 37 14...

Страница 9: ...480 295 130 2 260 910 1600 1850 1900 810 1730 610 100 1570 930 1500 1480 295 130 2 290 1100 2000 2000 1840 1000 2250 830 150 1570 930 1250 1210 345 130 2 350 1100 2000 2000 2090 1000 2250 830 150 2160...

Страница 10: ...ucing the number of ignition starts of the burner in case of adapting of a burner Reliability Energy savings Enviromental friendly Modern Design Solid Construc ion Easy maintenance Big fire box Large...

Страница 11: ...d pipe that crosses the rear plate and the combustion chamber and which has an optimal length to ensure a better air intake The ventilator is controled by the control panel and the conection of the ve...

Страница 12: ...ned in such a way that all its parts in touch with flames to be cooled by water The profile number and length of the smoke pipes are designed specially for a maximal exploitation of the exhausts The w...

Страница 13: ...ance fireproof doors and without woods for windows The boilers having the caloric flow of 0 1 Gcal h can be located in rooms having other destinations in which it will be arranged an appropriate space...

Страница 14: ...would be listed the work instructions that will consider the speciffic of the boilers in the room There will be also listed internal instructions concerning the operators task and the way of operatin...

Страница 15: ...ds grass etc The cleaning of the chimney esspecially in the exit points from the boiler and the elbows where the exhaust gases change their course A clean chimney means a correct draught The insulatio...

Страница 16: ...sons for malfunction of solid fuels boilers 1 Small active height of the chimney 2 Untight masonry of the chimney 3 Too narow masonry of the chimney 4 The existence of foreign parts or narowing of the...

Страница 17: ...70 boilers we have only one cover for the sides For the other boiler series we have two or three covers for the sides 7 THE CONTROL PANEL Digital Electronic Controller PWC 1000 Operating instructions...

Страница 18: ...maximum exhaust temperature that the fan power starts to decrease 08 IGNITION TIME Maximum time of the process ignition Fan power is determined only by the ignition air setting at this process 09 IGNI...

Страница 19: ...ng Increased fuel consumption Increasing temperature of exhausts Carbon layers Reduced draught Maintenance instructions Disassemble the burner if necessary Open the doors Disassemble the turbulators f...