Please read the following
instructions carefully in order to
make sure that the heater is used
properly and does not cause mal-
function.
1. Purpose
Hiton HP 30, HP 45, HP 80, HP 130
and HP 250 heaters are designed for
heating small and medium-size ro-
oms and surfaces in buildings without
central heating and water system.
Heat in form of hot air is transported
to the room either directly by the head
or by means of flues.
Heaters may be used in rooms where
other oil or gas heaters functioning in
ON-OFF mode are operating. Decision
about which heater should be used is
made by the user.
2. Construction of the heater
Heaters consist of the following units:
heat exchanger made of stainless
steel, radial fan, control panel with
security thermostat, outlet decom-
pression head with side dampers and
external casing painted with powder
coating. On the inside of the casing
are sheet zinc screens with deflectors
which provide additional isolation
against heat emission on the heater
panels.
It is recommended to use
burners which are approved by the
producer. If a different burner is
used the product may not comply
with safety requirements of the
European Directives.
Fig. 1
Heater construction
3. Storage conditions
Oil heater should be stored in the
following conditions:
Temperature
-20 - +85°C
Relative humidity
5-85%
Pressure
800-
1200hPa
Lack of dust/ pollu-
tion
V
Environment free of
chemical pollutants
V
4. Conditions for use
Oil heater should be operated in the
following conditions:
Temperature
0-30°C
Relative humidity
5-85%
Environmental impact
protection
IP20
Appropriate ventilation of
the heated area
V
5. Safety measures and gene-
ral recommendations
Heater should be installed, placed
and used in accordance with binding
regulations. Rules that should be
adhered to when operating the heater
are as follows:
• recommendations included in this
instruction should be meticulously
followed
• heater may not be installed in pla-
ces where there is a risk of fire or
explosion
• combustible materials should be
placed away from the heater (mini-
mum 3 meters)
• there should be appropriate ven-
tilation in room(s) heated with oil
heater to assure good functioning of
the burner
• burner should be placed close to a
flue or a flue pass and appropriate
power distribution board. Burner
should be protected against chil-
dren and animals.
Burner should be powered off after
use.
Do not exceed maximum heating
performance.
Assure appropriate air circulation in
both sucking in and blowing out the
air.
6. Installation
Installation and activation of the
heater should be carried out by an
authorised/certified fitter nomina-
ted by the seller
• When installing the heater, all local
regulations are to be complied with,
including regulations referring to
national and European norms.
• Place the heater on level, concrete
surface.
• Level the heater.
• The heater should be placed away
from combustible materials.
• The heater must be connected to
exhaust fumes channel according
with binding norms, including the
following recommendations:
• Combustion outlet flue should
be as short as possible facing
upwards.
• It should not have any sharp
curves or bends and its diameter
should under no circumstances
be reduced compared to the size
of the vent cap.
• Each heater should be connected
to a separate combustion flue.
• Draught may not be lower than
the minimum draught required
as per technical specifications.
• Flue has to be at least 1 meter
long.
• Burner should be fitted to the he-
ater by means of attached screws.
• Attached insulating gasket should
be placed between the burner and
the heater.
• Burner should be fitted to the fuel
tank according to the ‘Burner In-
struction of Use’.
• Installation powering the heater
must be grounded and equipped
with electro-magnetic thermal
release. -1,5 mm2 diameter po-
wer cable must be connected to
switchboard equipped with breaker
switch. -Thermostat or digital timer
should be connected to heater con-
trol panel.
7. Description of use
and operation
Switching on
Mode switch located on the control
panel should be set at HEATING or
COOLING. In the COOLING position,
the fan is immediately switched on.
Setting threshold temperature or
ENG
Содержание HP 130
Страница 3: ...HITON heat your home not the planet 3...
Страница 4: ...4...
Страница 11: ......
Страница 16: ......
Страница 22: ......
Страница 23: ...24 LIMIT 90 1 2 RU...
Страница 24: ...HITON heat your home not the planet 25 3 400 50 RU...
Страница 25: ...26 RU 1 HITON HP 30 45 80 130 250 ON OFF 2 1 3 20 85 C 5 85 800 1200hPa V V 4 0 30 C 5 85 IP20 V 5 3 6 1...
Страница 26: ...HITON heat your home not the planet 27 RU 1 5 2 7 30 45 80 130 250 90 9 1 30 45 1 3 20 35 40 LIMIT 90 0...
Страница 27: ...28 RU 9 1 2 1 2 LIMIT 1 1 2 3 1 1 RM 5 2 1 1 1 2 3 4 5 1 2 3 4 1 2 1 2 1 1 1 31 41 43 30 a 8 2...
Страница 28: ......