![THERMOROSSI Ecotherm Compact Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/thermorossi/ecotherm-compact/ecotherm-compact_installation-use-and-maintenance-manual_1106068023.webp)
pag. 23
INSTALLATION
4.8 EXAMPLE OF HYDRAULIC DIAGRAM FOR H
2
O HEATER/COMPACT ONLY HEATING
4.8 EXAMPLE OF HYDRAULIC DIAGRAM FOR H
2
O HEATER/COMPACT ONLY HEATING
A: Heating system delivery
R: Heating system return
S: gate valve
VNR: non-return valve
VEC: expansion tank closed to protect system
VR: pressure reduction valve
Drain
From water supply
system for replenishment
A: Heating system delivery
R: Heating system return
S: gate valve
VNR: non-return valve
VEC: expansion tank closed to protect system
VR: pressure reduction valve
From water supply
system for replenishment
Drain
CAUTION:
The temperature of the water in the boiler tube is not adjustable in this case and it depends on the temperature
of the water delivery to the plant, that is the SET POINT temperature.
Boiler tube with
interspace