The heater / boiler must be energised and the switch at the back turned to position “1”.
Your heater / boiler informs you on its operating status and on any problems that could arise by means of voice messages. Select the volume
level for the voice messages by carrying out the following procedure. When the insert is in the
POWER OFF
,
POWER ON
or
RUNNING
status
simply press the button
(19)
until the word
VOLUME
appears on the display
(10).
Press button (2) and the word SELECT appears on the
display:the introductory music plays. Press button
(4)
repeatedly and the
+
symbol appears
(to increase the volume)
.
Press button
(3)
repeatedly and the
-
symbol appears (to lower the volume). To confirm the volume selection press the button
(1).
The heater then returns to
its previous
POWER ON
or
RUNNING
or
POWER
OFF
status.
5.1.5 LANGU
5.1.5 LANGU
5.1.5 LANGU
5.1.5 LANGU
5.1.5 LANGUA
A
A
A
AGE SELECTION
GE SELECTION
GE SELECTION
GE SELECTION
GE SELECTION
The heater / boiler must be energised and the switch at the back turned to position “1”.
Press the MENU’ button
(19)
repeatedly until the word
ITALIAN
appears on the display
(10)
. To change the display language proceed as
follows: Press button
(2)
and the
SELECT ITALIAN
text appears on the display. Press the button
(4)
repeatedly to select German, English,
French, Spanish. Once you have selected the desired language press button
(1)
: The handheld radio control carries out a data analysis, that
is, an update of the new language.
5.1.6 OPERA
5.1.6 OPERA
5.1.6 OPERA
5.1.6 OPERA
5.1.6 OPERATING LEVEL SETTING
TING LEVEL SETTING
TING LEVEL SETTING
TING LEVEL SETTING
TING LEVEL SETTING
The heater / boiler must be energised and the switch at the back turned to position “1”.
Your appliance is delivered with an excellent program installed that favours combustion yield; the program is called
Level 1
.
If you are using pellets with a higher than normal incidence of residues after combustion in the brazier, alternative levels may be selected:
Level 2
: this program increases the smoke suction unit speed acceleration.
Level 0
: when using lightly-compressed pellets and/or flue outlets with very high vacuum, over 2 mm water column.
The pellet consumption value is not affected by the operating level settings.
Select the required level by acting as follows:
Press the
(19)
button on the back of the radio control repeatedly until the text indicating the preset heater / boiler level appears on the
display.
(Level 1 or Level 2 )
. Press the button
(2)
and the word
SELECT
appears on the display
(10)
. To change the operating level hold
down button
(3)
and press button
(4)
. By holding down button
(3)
and pressing button
(4)
repeatedly the level changes in the following
sequence:
Level 2
... ...
Level 1
.
5.1.7
5.1.7
5.1.7
5.1.7
5.1.7 W
W
W
W
WA
A
A
A
ATER PRESSURE IN
TER PRESSURE IN
TER PRESSURE IN
TER PRESSURE IN
TER PRESSURE IN THE GENERA
THE GENERA
THE GENERA
THE GENERA
THE GENERAT
T
T
T
TOR
OR
OR
OR
OR
The water pressure in the generator can be viewed on the radio control, see par. 5.2.
The level selection can be made with the heater / boiler
OFF
or
ON
. If the change is made while the insert is running the
difference in the flame will be apparent. It is mandatory to pay particular care when selecting the most appropriate
operating cycle for your installation. After the selection of the operating cycle a thorough cleaning of the brazier is
mandatory.