Technical Manual

• 

The unit requires a cold drinking water connection. 

• 

The distance between the machine and the water connection should not be more than 100 cm (40 inches).  

• 

To connect the unit, use only the supplied original hose.

• 

The water pressure must be between 2 und 4 bar (29 - 58 psi) If the water pressure is more than 4 bar (60 psi), you have 

to install in a pressure reducing valve. Use an according booster pump if the net water pressure is very low or if there is no 

net water pressure (water from water tank). 

• 

All national and regional rules and directives are to be followed. Contact an expert if you have questions.

WATER 

CONNECTION

WATER QUALITY

• 

The water quality has a big impact on the quality and the taste of a coffee.

• 

Use a drinking water supply only! 

• 

The optimal total water-hardness is 5-8 dH° / 8-14 fH°. In most cases, the use of an acitve-coal filter is necessary. Contact 

an expert if you have questions.

• 

The distance between the water drain and the machine should not be more than 100 cm (40 inches). 

• 

It is important that the water drain (tube) does not hang down to allow proper draining.

• 

Make sure there is no back pressure in the drain system.

WATER DRAIN

For hygenic reasons the equipment must be cleaned before the start-up.

Caution:

 

• 

Do not clean the milk tank, bean hopper, grounds drawer or drip tray in high concentration alcohol based cleaners, such as 

cleaning alcohol, ethanol, methanol or other strong detergents. Also prohibited to use for cleaning are acetic acid etc. 

• 

Only use comercially available detergents.

• 

Do not put plastic parts, (polyamids), into microwave ovens at any time as the microvaves will affect and deteriorate the 

plastic material.

• 

Do not clean the machine with a jet of water.

CLEANING

Installation and putting into operation

Important indications

DISPOSAL

• 

The packaging material (cardboard, plastic, styropor) must be disposed of in compliance with statutory regulations.

• 

In order to avoid any accidents caused by inappropriate use, or in particular by playing children, the machine must be put 

out of operation and disconnected by an authorized service agent. Subsequently cut off plug from power cord.

• 

The correct disposal of the machine helps to prevent negative consequences for the environment. Dispose of the equipment 

according to the local rules and regulations. The manufacturer highly recommends the recycling of old machines.

When handling electronic components, the following safety indications must be considered:

• 

The tools used must be intact and approved by Thermoplan (see Technical Manual section „Tools and Accessories“).

• 

The electronic components must be kept away from moisture, dust, low-resistance materials, chemicals or lipids of any kind.

• 

The electronic components must be protected from electrostatic discharge at any time (ESD-packaging).

• 

The workplace area must be fitted with a ESD-conform protection with a protective resistor of 1MΩ.

• 

To avoid damage due to static charge, the service technician must be grounded with a protective resistor of 1MΩ when 

working with electronic components.

HANDLING OF 
ELECTRONIC 
COMPONENTS

Содержание Black&White3 CT

Страница 1: ...2 1 REV 5 SECTION 2 2015 by Thermoplan AG Subject to change Technical Manual Installation Initial Start Up Safety ...

Страница 2: ...st edition SO 1 2011 08 30 Different modifications RE 2 2013 11 11 Revision for US market SO 3 2014 11 18 New machines added B CTMC CTM RU added layout changes MST 4 2015 06 01 New section added Handling of electronic components MST 5 2016 02 26 Added installation instructions of UT under counter refrigerator RZ 6 7 8 9 10 Document Installation startup and security ...

Страница 3: ... 5 SECTION 2 2015 by Thermoplan AG Subject to change Technical Manual Index Installation 2 4 2 5 Installation refrigerator 2 6 2 7 Start up 2 8 The way to perfect coffee enjoyment 2 9 Safety in operation 2 10 ...

Страница 4: ... simple adapters and extensions and the limit power load shown on multiple adapters When the unit is permantly connected to a field terminal a disconnect switch must be installed at the field terminal The disconnect switch shall disconnect all lines from power net except grounding To prevent dangerous overheating uncoil the power cord to its full length When the power cord or plug is damaged you m...

Страница 5: ...ther strong detergents Also prohibited to use for cleaning are acetic acid etc Only use comercially available detergents Do not put plastic parts polyamids into microwave ovens at any time as the microvaves will affect and deteriorate the plastic material Do not clean the machine with a jet of water CLEANING Installation and putting into operation Important indications DISPOSAL The packaging mater...

Страница 6: ... by one This drawing shows how the correctly installed connection looks like when looking from below This drawing shows how the cables are plugged correctly to connect machine and refrigerator The part correctly mounted is flush between the refrigerator and the machine Install part 2 see set above at the back of the machine Install part 1 of the set under the drip trays between refrigerator and ma...

Страница 7: ...ged correctly to connect a BW3 Connect the FEP pipe part 2 at the bottom back of the refrigerator and Connect the milk hose part 1 see set above to the available elbow connector on the left side of the refrigerator and the other end of the pipe to the connector at the bottom of the coffee machine Adjust the milk rinse times in the service menu according to the tube lengths used Recommended setting...

Страница 8: ...ee beans Coffee products can now be dispensed Fill chocolate hopper with chocolate powder for gastro machines Switch on refrigerator main switch on the bottom of RF Fill the milk container with milk All products can now be dispensed CAUTION Ensure hygiene The milk container has to be clean and dry Only use heat treated e g pasteurised or UHT milk Only fill the milk container using milk already ref...

Страница 9: ...ime is set optimally if no water drips into the cup Relax time During the relax time it is possible for the coffee powder to expand During this process the water already absorbes some of the flavour in the coffee powder For the ristretto and espresso the relax time has to be longer than for a long coffee for which only a short or no prebrew and relax time should be set The relax time is about the ...

Страница 10: ...cycles by a trained technician Unplug the power supply before servicing the machine General safety notes Strictly observe the following general safety notes Before moving the machine the milk container has to be emptied Move the machine with a lifting device or with the help of other people Use gloves and safety boots when moving the machine It is forbidden to modify or manipulate the machine The ...

Отзывы: