![Thermoplan Black&White3 CBT Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/thermoplan/blackandwhite3-cbt/blackandwhite3-cbt_technical-manual_1105907035.webp)
REV-4
3.35
SECTION 3
© 2009 by Thermoplan AG, Subject to change
Technical Manual
Menu Description
Menu
Description
CT
CTS
CTM cool
CBTM
44.
Filter x
not active
In the parameter Filter with the „Minus“ or „Plus“ key it is possible to program the amount of
water to be dispensed until the filter cartridge must be replaced.
Note:
Once the filter cartridge is replaced pressing the Double product key 3 times will reset the counter
to 0. The reset is confirmed by „OK“ shown on the display. The programmed credit is rest to 0 and
the amount of water is reconfirmed before the next filter replacement is due.
X
X
X
X
45.
Service counter
x
In the parameter „Service counter“ the total of all brew cycles will be displayed since the machine
was in operation. This counter cannot be reset.
X
X
X
X
46.
Tubtemp
74°C 165°F
In the parameter „Tubtemp“ the temperature for products dispensed from the tub can be set.
X
47.
Tubreadytemp
59°C 138°F
By pressing the „Minus“ or „Plus“ key in ther parameter „Tubreadytemp“ you can set the
minimum temperature needed for product beverages. If the temperature in the tub is below the set
temperature level, the message „Please Wait“ appears on the display and there will be a waiting
time until the boiler has reached the programmed temperature level.
X
48.
Milk temp
xx°C xxx°F
In the parameter Milk Temperature by pressing the Minus or Plus key the milk temperature can be
programmed.
- CTS: 54 - 97°C (129 - 206°F)
- The default value is 74 °C
X
49.
Calibratesensor
xx°C xxx°F
In the parameter Calibrate Sensor the milk temperature can be calibrated. A digital thermometer is
needed for this process to make sure that the correct temperature is measured.
X
50.
Grounds
800g
By pressing the „Minus“ or „Plus“ key in the parameter Grounds the number of coffee pucks
can be programmed before the message Empty Drawer will be displayed. The basic value can be
programmed between Not Active up to 1600 gramms. The basic factory default value is set at 800
gramms.
Note:
Due to hygenic reason if the coffee machine is not used ofteen it is recommended to set the
parameter to a lower value to make sure the drawer is frequently emptied.
The setting Not Active is used when no puck drawer is used in Self-Service operation where the
used coffee grounds fall through the bottom opening of the coffee machine‘s chassis, directly into
a waste bin.
X
X
X
X
51.
Coffeerevolution
1800rpm (1/min)
By pressing the „Minus“ or „Plus“ key you can change the revolution of the water pump during
coffee products.
X
X
X
X
52.
Tearevolution
1300rpm (1/min)
By pressing the „Minus“ or „Plus“ key you can change the revolution of the water pump during tea
products.
X
X
X
X
53.
Bypassrevolution
1000rpm (1/min)
By pressing the „Minus“ or „Plus“ key you can change the revolution of the water pump during
products with bypass.
X
X
X
X