Alarm 01:
PT100
Inconsistent interpretation of the reading -
Probe signal lost (sensor or cable). The heating
control is instantly disabled.
Alarm 02:
Platen overheating
Temperature reading above 240° C.
The heating control is instantly disabled.
Alarm 06:
Platen lift
The top travel limit is not read during the lift
phase before the platen lift time-out ends.
Alarm 10:
Pb COM.
Communication between the power board
and the screen board interrupted.
Contact your reseller.
Alarm 13:
Temperature setpoint not reached
Rising or falling temperature triggers
or – 30° C maximum around the setpoint.
Press in the red zone to clear the fault. The work page will be displayed.
3.4 Pressure Adjustment
The pressure is obtained by decreasing the gap beween the upper hot platen and the lower cold platen.
• Loosen the nut to unsecure the pressure adjustment wheel.
• Turn the wheel on the top of the heating plate: clockwise to increase the pressure,
• counter clockwise to decrease the pressure.
• Tighten the nut back to lock and secure the pressure ad-justment wheel.
List of alarms/events:
Pressure Adjustment wheel
Electromagnet
Heating Plate