1.
Locate bus connection (HPT and FP only)
and cable as shown. Cut end of cable at
angle to aid in piercing grommet. Leave
additional cable for expansion loop. See
page 5 for multiple cable installation tips.
5.
Insert banding guide into expediter and
snap into place.
3.
Insert cable into expediter. If mounted on
bottom or side of pipe, punch out weep hole.
Note: For HPT and FP cable, exchange
grommet in Terminator with grommet
provided in PETK-3-ECM.
4.
Slide expediter toward pipe and route
cable through support base entry.
8.
Terminate cable with appropriate PETK
termination kit. Refer to PETK installation
instructions.
9.
Push excess cable back through
expediter. Tighten cap securely. Tape
cable expansion loop to pipe.
6.
Mount expediter to pipe using pipe band.
Do not band over cable.
7.
Cut off end of cable.
Terminator
TM
ECM-P-XP
INSTALLATION PROCEDURES
2.
Position RTD Sensor(s) in grommet (when
applicable). Do not pull from the sensor
end when routing through the expediter
assembly. Pull sensor from the lead wire
portion.