Kit Contents
Tools Required
Receiving, Storing and Handling
1. Inspect materials for damage incurred during shipping.
2. Report damages to the carrier for settlement.
3. Identify parts against the packing list to ensure the proper
type and quantity has been received.
4. Store in a dry location.
Dimensions
Terminator
TM
DE-B Beacon
Item
Quantity
Description
1
1
Expediter Assembly
Grommet Compressor
Grommet
Support Base with O-Ring
2
1
Light Module Cover
3
1
Banding Guide
4
1
Banding (fits 10" pipe and below)
5
1
LED Light Module
210 mm
(8.25")
76 mm
(3")
89 mm
(3.5")
64 mm
(2.5")
2
4
3
5
Order Separately
SCTK Connection Termination Kits (per cable)
SCTK-1D
for BSX, RSX, VSX, VSX-HT
SCTK-2D
for KSX, HTSX
SCTK-3D
for FP, HPT
Order Separately
SCTK Terminal Block Connection Kits (per cable)
SCTK-1TB
for BSX, RSX, VSX, VSX-HT
SCTK-2TB
for KSX, HTSX
SCTK-3TB
for FP, HPT
Item
Quantity
Description
1
2
Connection Boots
2
1
Large Wire Nut
3
2
Medium Wire Nuts
4
2
Small Wire Nuts
5
1
RTV Tube
6
1
GRW-G Grommet (SCTK-3D only)
Item
Quantity
Description
1
1
Terminal Block
2
1
Terminal Block Mounting Screw
3
1
Splice Connection Boot
4
1
RTV Tube
5
1
GRW-G Grommet (SCTK-3TB only)
6
1
IP66/Type 4X -60°C ≤ Ta ≤ +45°C, T6
-60°C ≤ Ta ≤ +55°C, T5
Ordinary & Hazardous Locations
Class I, Division 2, Groups A, B, C, & D, Zone 2 IIC T6...T5
Class II, Division 2, Groups F & G, Class III
Certifications/Approvals
Installation Precautions
• To minimize the potential for arcing and fire caused by product
damage or improper installation use ground-fault protection.
The National Electrical Code (NEC) and Canadian Electrical
Code (CEC) require ground-fault protection of equipment for
each branch circuit supplying electric heat tracing.
• Installation must comply with Thermon requirements and
be installed in accordance with the NEC, CEC, or any other
applicable national and local codes.
• Component approvals and performance ratings are based on
the use of Thermon specified parts only. User supplied power
connection fittings must be listed or certified for intended use.
• De-energize all power sources before opening enclosure.
• Keep ends of heating cable and kit components dry before and
during installation.
• Individuals installing these products are responsible for
complying with all applicable safety and health guidelines.
Proper personal protective equipment, or PPE, should be
utilized during installation. Contact Thermon if you have any
additional questions.
1
2
4
3
5
2
4
3
5
1