E.19 Energy Management System (EMS)
Adding the EMS allows a heater to operate
automatically, or to act as a weather station when part
of a network of heaters controlled by the Fastrax®
RCMS.
The system includes a module, a precipitation
detector, ambient temperature sensor, and rail
thermostat. Once installed, the controller recognizes
the EMS module and works in conjunction with it.
Controls:
NOTE:
These settings are true for AUTO mode only, with the
exception of the TEST switch.
These setting are overridden when operated in REMOTE
SCADA mode by the corresponding Fastrax
®
RCMS software
parameter.
1.
SNOW-RAIN
:
1.1
This dial adjusts the temperature set point
between -12°C to +12°C.
1.2 Precipitation detected when the ambient
temperature is below this set point is
considered snow or above it is rain.
2.
LOW TEMP
:
2.1
This dial adjusts the temperature set point
between –55°C to +5°C.
2.2
The EMS will not request the heater to operate
when the ambient temperature is below this set
point and snow is detected.
3.
DELAY ON
:
3.1
This dial sets the length of the delay, 0 to 30
minutes, before making the heater request.
3.2
When snow is sensed continuously for the
duration of the delay on period the heater
request is made. If at any time during the delay
snow is not sensed the timer is reset.
4.
DELAY OFF
:
4.1
This dial sets the length of the delay, 0 to 60
minutes, before removing the heater request.
4.2
When snow is no longer sensed the heater
request is held for the duration of the timer. If
at any time during the delay snow is sensed the
timer is reset.
5.
TEST:
5.1 This switch simulates precipitation when ON.
Used to test the module operation.
6.
SENSITIVITY
:
6.1
This dial adjusts the precipitation detector
sensitivity between the least, 1, and most, 6. For
example, when set at 1 the detector has to be
very wet to indicate precipitation.
7.
INDICATIONS
:
7.1
On the module are a number of status LED’s
intended to aid the user’s understanding of the
state of operation. See table for full description.
Table 1 – Status LED’s
LED
Name
Description
State
Indication
STATUS
Processor status
Green with
a red pulse
Processor
functioning
normally.
Off
Solid green
Solid red
Processor failed.
POWER
Power supply
On
Module energized.
COMM
Communications
Flashing
Indicates
communications
with controller.
HEAT ON
Heater request
On
EMS request to
turn on heater.
LOW
TEMP
Low Temperature
On
Ambient
temperature is
below set point.
Heater will turn off
or not turn on if
requested.
DELAY
TIME
Delay Time
On with a
pulse off
Delay active.
Delay on when
HEAT ON is off.
Delay off when
HEAT ON is on.
Off with a
pulse on
No delay.
SENSOR
WET
Precipitation
sensor wet
On
Precipitation
above set point.
Содержание HELLFIRE 400
Страница 26: ...26 26 Installation Figure 2 140 Clearance Figure 3 155 Clearance...
Страница 27: ...27 27 Installation Figure 4 Clearance Turned 90 Degrees...
Страница 39: ...39 39 THERMON HEATING SYSTEMS INC Heater Specifications...
Страница 40: ...40 40 THERMON HEATING SYSTEMS INC Heater Specifications...
Страница 41: ...41 41 CCI THERMAL TECHNOLOGIES INC Heater Specifications...
Страница 42: ...42 42 THERMON HEATING SYSTEMS INC Heater Specifications...
Страница 54: ...54 54 NOTES...
Страница 55: ...55 55 NOTES...