background image

P a g e

 | 

11 

 

28-7-09 

 

 

 

                Contact your Thermoline representative for details on all options available. 

 

PRODUCT WARRANTY 

 

 

  This warranty is limited to goods purchased and installed in *Australia. 

Twelve (12) months full warranty on parts and labour by Thermoline Scientific 
through its authorised dealers or service organisations, will repair or at its 
option replace any part found to contain a manufacturing defect in material or 
workmanship without charge to the purchaser for parts, service labour or any 
necessary shipping or cartage costs for parts only. Replacement or repaired 
parts will be warranted 

only

 the 

unexpired

 portion of the original warranty. 

This warranty does not apply to damage caused by accident, misuse, fire, 
flood, or acts of God. It does not apply to damage caused from failure to 
properly install, operate or maintain the goods in accordance with the printed 
instructions provided. To obtain prompt warranty and service, simply contact 
Thermoline Scientific. 

 
 

  If warranty service is required, Thermoline Scientific will endeavour to have 

an authorised service organisation carry out the work if there is an available 
agent, however if it is decided to return the equipment to our main workshop 
then it is the customers responsibility to pay the freight cost of this return, 
Thermoline Scientific, after the repair, will return the goods at our cost, to the 
customer. 
The customer should always contact Thermoline Scientific for approval to 
return and seek advice as to the best and most cost effective method of 
return. 

 

 

 

*Export Warranty:

 Limited to the replacement of 

Parts Only

. Supplied Ex 

Factory, Australia. 

 

 

Limitation of Liability:

 Except to the extent not permitted by law, Thermoline 

Scientific excludes all warranties, conditions and terms implied by law. If any 
implied warranty, condition or term does exist, Thermoline Scientifics’ liability 
for breach of that implied term is limited, at the option of Thermoline Scientific, 
to replacement or repair of goods or part thereof, or payment of the cost of 
repairing or replacing the goods or any part of the goods. 

Содержание TI-1000F

Страница 1: ...ty Ltd T A Thermoline Scientific ABN 80 000 859 129 10 12 Ross Place Wetherill Park N S W 2164 Australia P O Box 6862 Wetherill Park Delivery Centre N S W 1851 Australia Phone 02 9604 3911 Internation...

Страница 2: ...e is a Possibility of damage to the Equipment To maintain safe operation of this equipment be aware of the ALERT BOXES located throughout these operating instructions CONTENTS SAFETY INFORMATION 2 ALE...

Страница 3: ...he packaging materials until the equipment has been thoroughly tested Notify the detail of any damage without delay to your supplier or Thermoline Scientific LOCATION Place the equipment in on a firm...

Страница 4: ...ing conditions The door s close on a magnetic gasket and are further secured with positive action door latch es The external is powder coated steel The desired operating temperature is set at the temp...

Страница 5: ...eel is under most conditions extremely resistant to corrosion This is in part due to the addition of chromium and nickel to the steel and the formation of a durable chromium oxide at the surface durin...

Страница 6: ...ues to trip it may indicate an electrical fault exists Switch Off the power and consult a qualified technician TEMPERATURE CONTROLLER SENSOR This is a Eurotherm 3216 PID control with digital temperatu...

Страница 7: ...ment as fire or explosion may result This cabinet contains components that may ignite such materials WARNING 2 Do not introduce water into this equipment as the excessive vapour may result in prematur...

Страница 8: ...ntroller shifting the input value of the sensor This correction value is first entered when the equipment is under test at the factory Further small adjustments can be made by the operator to compensa...

Страница 9: ...t value with few exceptions is between 0 5 and 1 5 The need to use a value outside this range should be carefully considered If in doubt return the value to zero and recalculate the offset value The s...

Страница 10: ...able to accept the 4 20mA signals representing 0 0 to 100 0 C and 0 to 100 RH Maximum load to be applied to the analogue output is 500 ohms Pin connections for retransmission socket ALARMS No volt al...

Страница 11: ...imply contact Thermoline Scientific If warranty service is required Thermoline Scientific will endeavour to have an authorised service organisation carry out the work if there is an available agent ho...

Страница 12: ...y by Any defect in material or workmanship of or any other defect whatsoever in or unsuitability for any purpose of the goods or any part of the goods or default or negligence on the part of Thermolin...

Отзывы: