Page 22
the unit by pulling it towards you. Please see Fig. 16a. Also remove the main drain tube from the rigid drain
pipe attached to the wall and check that both tubes are clean and clear from deposits.
16.6
CAUTION:
Check that the water tank is not too hot to handle. Unfasten the latches around the water
tank and remove the tank bottom from the main body of the tank vessel by pulling it down carefully in a twisting
motion. Reminder: there should be a small amount of water left in the tank. After you remove the tank, clean
the round o-ring gasket, but don’t discard it.
NOTE
:
This round gasket is mandatory and the tank will not seal properly without it, likely resulting in
a water leak.
16.7 There will be varying degrees of scale on the tank bottom/sidewalls and interal components which is a
normal byproduct of boiling water containing minerals. Simply discard the scale from the bottom of the tank,
leaving the scale on the tank sidewalls and elements (it will not adversely affect the operation of the unit).
Clean the scale from the bottoms of the stainless steel water discharge and water supply tubes using vinegar
or a cleaning product designed to remove scale, lime or calcium to enable unresricted water
fl
ow. If scale is
excessive, affecting the
fl
ow of water replace the drain tube and sensors when necessary (normally every 2-4
years); these replacement parts are included in a maintenance kit available from your installing contractor. DO
NOT use any acids when cleaning your Acu-Steam PRO humidi
fi
er.
16.8 Once completed, reinstall the o-ring gasket around the bottom tank collar. Please see Fig. 16b. Align
the latches around the tank and the
fi
xed part while lifting the tank in place. Please see Fig.16c. Apply even
pressure to secure the tank properly in the tank cover. Then close the latches in an alternating sequence
similar to Fig. 16d while holding the tank in position. The latches should close with minimal pressure. Verify
that the o-ring gasket and tank are seated properly by checking for leaks when re-starting the humidi
fi
er.
Fig. 16b
Fig. 16c
Pro7
Steam Outlet
1
2
3
6
5
4
Fig. 16d
Содержание Acu-Steam PRO 12
Страница 2: ......
Страница 4: ...Page 2 2 Overview and model specifications PRO 23 1 4 13 1 2 20 Ø 3 Ø 1 1 4 13 12 12 5 8 13 1 2 8 6 ...
Страница 28: ...Page 26 19 Wiring diagrams ...
Страница 29: ...Page 27 ...