When  connecting  the  pellet  stove  to  the  chimney,  smoke  pipes  with  a  diameter  of 

80mm and temperature-resistant gakets must be used. It is recommended to install a 
T-piece with revision or a knee after the chimney outlet, and a piece of flue pipe of a 
length of min. 0.5m and then connect the stove to the chimney. It is not recommended 

to connect directly between the stove and the chimney without flue pipes. It is also 
not recommended to attach a connection of the flue pipes on the left or right, which 
means you do not make knee in the flue pipes in the sides. 

 

 

 
 

 
 
 

 
 
 

 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 

 

Содержание Minitherm AQUA

Страница 1: ...ThermoFLUX d o o Bage br 3 70101 Jajce Bosnia and Hercegovina Tel Fax 387 30 657 100 www thermoflux ba tfinfo thermoflux ba PELLET STOVE USER AND MAINTENANCE MANUAL...

Страница 2: ...2...

Страница 3: ...3...

Страница 4: ...ng room 10 2 11 Fresh air supply 10 2 12 Safety devices 10 3 General overview 12 3 1 GSM modem 12 3 2 WI Fi module 12 3 3 Technical data 13 4 Installation and commissioning of the stove 14 4 1 Install...

Страница 5: ...ove 30 6 1 Ignition 30 6 2 Shutting down of stove 31 6 3 Stove power adjustments 31 6 4 Adjustment of water temperature 32 6 5 Modulation 32 6 6 Cleaning of FIRE POT 33 7 Cleaning and maintenance 34 7...

Страница 6: ...he Minitherm AQUA stove 1 3 Technical changes ThermoFLUX continuously develops and improves its stoves The information in this version is correct at the time of going to press All details in this manu...

Страница 7: ...nd then are ignited with an electric heating cartridge Depending on the set value of the power the pellet conveyor automatically adds the required amount of pellets The required air supply for combust...

Страница 8: ...ed wood pellets and standards Thermo FLUX d o o recommends wood pellets with a diameter of 6mm and a length of 10 30mm Other requirements on the fuel result from either standard O Norm M 7135 DIN plus...

Страница 9: ...marked with this symbol may only be done by a qualified electrician WARNING Warning about a dangerous location Work on areas marked with this symbol can lead to serious injuries or to extensive materi...

Страница 10: ...made according to current regulations especially regarding fire protection Storage of flammable materials cleaning agents and similar materials must not be stored in the boiler room The stove should...

Страница 11: ...itherm AQUA 11 Safety limit Thermostat STB intervenes by breaking the circuit in the stove automatically stops motor of the auger and exhaust gasses fan if the stove temperature reaches the limit of 9...

Страница 12: ...nternet Compatible with Android IOS and Windows devices The user can have full control over boiler via the application The Minitherm Aqua stove is compact and requires less than 1m2 for installation s...

Страница 13: ...temperature o C 80 9 Max working pressure bar 2 5 10 Height to center of flue pipe mm 198 5 11 Depth mm 575 12 Width mm 480 13 Height mm 945 14 Color red black 15 Flue pipe diameter mm 80 16 Inlet ou...

Страница 14: ...zed service for the first start must control the functioning of the stove at least during one full operating cycle In some countries it is obligatoy for first commissioning to be controled and autoriz...

Страница 15: ...ich would enable the cleaning of inner parts especially the horizontal parts Smoke pipe should be installed fixed It would be good to leave safety gates that could do the Minitherm r cleaning especial...

Страница 16: ...ion can be achieved in different ways One way is to easily open the cleaning door We recommend to install the draft regulator The pellet stove can not be connected To the chimney or the flue pipe to w...

Страница 17: ...with revision or a knee after the chimney outlet and a piece of flue pipe of a length of min 0 5m and then connect the stove to the chimney It is not recommended to connect directly between the stove...

Страница 18: ...Minitherm AQUA 18 4 3 Hydraulic schemes for connection...

Страница 19: ...ssibility to place the room thermostat in one room and does not need to be in the same room where the pellet stove is Operation of the stove with an external thermostat connected to the room thermosta...

Страница 20: ...tions Button Description 1 Increasing temperature and program functions adjusting days time 2 Decreasing temperature and program functions adjusting days time 3 Changing accepting program 4 ON OFF pro...

Страница 21: ...ciple of the stove operation is very simple When button for start is pressed stove goes into IGNITION MODE START is displayed and after that PELLET IGNITION Usually this phase lasts for 5 15 minutes d...

Страница 22: ...Minitherm AQUA 22 5 3 Schematic representation of the menu control By pressing button SET we enter general menu...

Страница 23: ...Minitherm AQUA 23...

Страница 24: ...Minitherm AQUA 24 5 3 1 Clock adjustments Clock adjustments can be done on following way...

Страница 25: ...ies to all days in the week Scheme 2 WEEK PROGRAM in this mode we can set 4 four different times for ignition and shutting down In this mode we can choose day in the week MON SUN in which we want stov...

Страница 26: ...Minitherm AQUA 26 Flow chart 2 Flow chart 3 Flow chart 4...

Страница 27: ...talled sensor for air temperature Connection for room thermostat is delivered overbridged which means that contact is closed 1 FUNCTION STAND BY SET ON In the case that function STAND BY is activated...

Страница 28: ...king power will change to lowest Stove will shut down only if temperature of the air in the system is 80 degrees C and on display is written WAITING COOLING Stove will start again when temperature in...

Страница 29: ...stove On display information is randomly changed about air temperature in the stove flue gasess temperature fan RPM etc To enter this option press SET after that with buttons 5 or 6 we choose MENU 07...

Страница 30: ...g things needs to be checked Silo needs to be filled with pellet Silo doors needs to be closed Combustion chamber basket needs to be cleaned Ash pot needs to be clean All doors on stove needs to be cl...

Страница 31: ...Stove power adjustments During working phase it is neccesary to set working power in which we want stove to work Adjustments of the working power is possible in the range from 1 5 and selection of des...

Страница 32: ...k and changes power to lowest Modulation starts 4 C below set temperature EXAMPLE We have adjusted water temperature on 73 C and power 5 regulation will work in power 4 when temperature is 70 C on 71...

Страница 33: ...n basket fire pot after certain time This phase is shown on display and work of the stove is set to lower power and suction fan is working on maximun for certain period of time as set in the factory W...

Страница 34: ...ion Using safety gloves take the firebox out and empty its content into a fire resistant container Clean the holes in the firebox with an appropriate screwdriver if neded Put the firebox back onto the...

Страница 35: ...xchange tubes before cleaning of ash pot and braizer basket Turn the stove off and wait until it has been cooled Remove the cover behind door 1 remove two nuts 2 and with the steel brush clean the pip...

Страница 36: ...as chamber Clean the sediments out of the tube heat exchanger using the vacuum cleaner Check if there is any ash left in the firebox or in the ash pan and clean them in accordance with the instruction...

Страница 37: ...illing A foreign object stuck dosage spiral clean Poor quality pellets wet pellet long pellets dust into pellets change the type of pellets Pellet igniter is defective replace it Contact Service Resta...

Страница 38: ...Minitherm AQUA 38 BLACK OUT The stove is out of power Reset alarm and start again...

Страница 39: ...disposed on landfills for metal stove cover metal sheets feeding system except motor braizer basket Electronic components can be recycled Glass glass wool and plastic parts can be recycled on landfil...

Страница 40: ...be done by authorised service or person authorised by ThermoFLUX or authorised importer distributor Stove must work in accordance with terms and conditions given in this manual Stove needs to be insta...

Страница 41: ...Minitherm AQUA 41 11 EU Label...

Страница 42: ...Minitherm AQUA 42...

Страница 43: ...Minitherm AQUA 43...

Страница 44: ...Minitherm AQUA 44 User manual MINITHERM LCD ENG 2019 ThermoFLUX d o o Bage br 3 Jajce Bosnia and Herzegovina Tel fax 387 30 657 100 www thermoflux ba...

Отзывы: