Mounting Instructions
2. Mounting Instructions
Electrical installation
The appliance must be permanently connected to fixed wiring.
The device has been prepared for connection to the electrical supply�
Elex 3�5MHBL and Elex 3�5MEBL require a 110-120V, single-phase supply, other mod-
els require a 208-240V, single-phase supply�
Please take reference of the rating plate
on device�
Please take reference of the following diagram to connect power supply with Elex
3�5/4�5/5�5 MHB/MEB which rated 240V�
NOTE: The wire has been attached to the appliance.
GR
GR
L2
L1
Circuit
Breaker
WIRE
Thermoflow
TM
Tankless
Water Heater
Electric
Panel
240V~
60Hz
Please take reference of the following diagram to connect power supply with Elex 3�5
MHBL/MEBL which rated 120V�
NOTE: The wire has been attached to the appliance.
GR
GR
N
L
Circuit
Breaker
WIRE
Thermoflow
TM
Tankless
Water Heater
Electric
Panel
120V~
60Hz
Circuit diagram for Mini Basic Series Elex 3.5MHBL