TM
Electric Tankless Water Heater -
Installation Manual and User Guide
15
EN
Mounting Instructions
The appliance must be earthed properly!
The filter mat contained in accessory bag must be installed when connecting
with inlet(cold) water pipe or hose!
Ground fault circuit interrupter must be installed with the appliance, please take
page.16 to 18 for the selection of interrupter.
Please verify the voltage of power supply before installation!
Drawing A / B - Installation as under/over -sink model
The device must be installed as shown in the installation drawing on the page�12 to
1� Mount the bracket on the wall and fix using two screws in the accessory bag, the
bracket should be upward(undersink) / downward(oversink)�
2� Place the appliance on the wall bracket and snap it into position� The outlets of ap-
pliance should be upward(undersink) / downward(oversink)�
3� Tap connection: Cold water inlet (blue) and hot water outlet (red) are marked on the
rating plate (under the rating plate cover)� Connect the appropriate pipe or hose of
the sanitary tap with the red-marked hot water outlet�
4� Connect power cable L, N and GROUNDING (120V models) to the power supply (
4a
),
or connect power cable L1, L2 and GROUNDING (240V models) to the power supply
(
4b
), then switch on the circuit breaker�
e-mini manual thermoflow -na.indd 15
2020/3/25 15:20