OPERATING INSTRUCTIONS

TROUBLE SHOOTING

Note: 

In the event of the unit shutting down due to being connected to a power source prior to being filled 

with water perform the following steps:

Unplug the unit and let the unit cool down for a minimum of 20 minutes.

Fill the unit with water after the cool down period.

Press the ‘RESET’ button at the back of the unit. 

Note: White substance in water means there is too much scale deposit in tank. This requires the unit being 

disassembled and drained.

Note: Grey or brown substance in water indicates the internal magnesium anode has dissolved (see 

Maintenance section for more info)

Thermostat 

Thermostat (Operating Setting)

Note: 

Use above table to keep unit at desired temperature levels

Cold; heater is switched off.

Automatic frost protection active; the device switches on if the water temperature falls 

below 45

o

F / 7

o

C.

Water temperature has risen by approx. 77

o

F / 25

o

C.

Water temperature is +/-165

o

F (+/-75

o

C).

Energy-saver mode/reduced energy consumption:

Greater energy savings are possible if the water temperature is set to a maximum of +/-131

o

(+/-55

o

C). This also reduces the risk of damage to the device.

05

 2.6 Gallons Water Heater - 

User Manual

TM

Содержание 2.6 Gals

Страница 1: ...Electrical Mini Tank Water Heater Installation uide ser anual and Warranty nformation TM Electrical Mini Tank Water Heater 2 6 Gals TM...

Страница 2: ...e maintains the water temperature at approximately 45 F 7 C to keep it above freezing without expending much energy If the device is to be disconnected from the power supply it must be emptied complet...

Страница 3: ...wo brass bushings included in Purchase 1 Tee 2 Safety valve set at 116 PSI with funnel 3 Reducing Tee 1 x 1 x 1 4 Flexible plastic hose 1 diameter 5 Hose clamp 6 Metal braided flexible hose 7 Metal br...

Страница 4: ...socket The device must be directly connected to an outlet power supply of 120V via an electrical cable or plug Note Connection of the device to the power supply must be made in accordance with the NEC...

Страница 5: ...Note Grey or brown substance in water indicates the internal magnesium anode has dissolved see Maintenance section for more info Thermostat Thermostat Operating Setting Note Use above table to keep un...

Страница 6: ...run at maximum temperature tap at minimum flow before reusing Pipes should be flushed for one minute The magnesium anode protects the tank against corrosion This is a cathodic process during which the...

Страница 7: ...long the warranty period nor initiate a new warranty period This warranty shall not cover errors due to improper installation or incorrect usage incorrect operating conditions or improper maintenance...

Страница 8: ...2 6 Gals TM...

Отзывы: