MOUNTING

 

 

Fix the two mounting brackets to the ceiling or wall in the desired location (refer minimum bracket centre chart). Make sure 
the method of fixing (bolts or screws) will be more than strong enough to support the weight of the heater, allowing for 
strong winds and other conditions.

 

 

• 

Slide the 2 locking brackets into the groove on the back of the heater. Make sure the pins on the locking bracket are 
facing the matching holes in the top mounting bracket.

 

• 

Lift heater into position and secure the 2 locking brackets to the mounting brackets using the screws provided. Make 
sure the 2 pins on the locking bracket engage with the matching holes in the mounting bracket. The pins will allow for 
both horizontal or angle mounting as required

 

• 

Tighten  all  screws  and  tighten  the  round nut at  the top  of the  bracket,  so  it  locks onto  the  top  part of  the mounting 
bracket.

 

 

NOTE: The standard bracket allows for normal or angle mounting of the heater and is suitable for ceiling or wall mounting.

 

MODEL

 

B

 

MINIMUM DISTANCE (mm)

 

THN2000

 

490

 

Left: 

Suspension mounting using the standard 

mounting brackets

 

 

NOTE: Chains or wire not included

 

Содержание HEATSTRIP THN2000

Страница 1: ...Product Manual HEATSTRIP Nano Electric Heater Model No THN2000...

Страница 2: ...tant alloy it is suitable for use in most applications including difficult corrosive environments such as coastal areas For exposed or windy areas we would recommend the HEATSTRIP Intense or Max range...

Страница 3: ...40 Volts Nominal at 50 60 Hertz Single Phase CONNECTION 3 Core Cable 2 5mm2 APPROVALS AUSTRALIA NZ EU MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 1 8 m 2 1 m 2 3 m 2 5m Outdoors and 2 7m Indoors MOUNT...

Страница 4: ...over outdoor tables BBQ s lounges assembly lines or indoor work stations Often it is more practical and efficient to spot heat these areas Spot heating will help to reduce the initial capital cost as...

Страница 5: ...otprint is reduced The below table outlines the coverage HEATSTRIP Nano model in m2 based on 2 different scenarios For example in an outdoor area that is protected from prevailing winds by walls caf b...

Страница 6: ...For ceiling mounting heights more than 2 5m outdoors we recommend the use of the chains or wires to reduce the height of the heater to 2 1m 2 3m This will increase the effectiveness of your HEATSTRIP...

Страница 7: ...Wall Installation Ceiling Installation Angled Ceiling Installation Lights fans and sprinklers must NOT be below heater Surface Below Heater Lights fans and sprinklers must NOT be below heater Surface...

Страница 8: ...degrees to mount onto a beam it can also be used to suspend with chains The brackets need to be mounted onto a secure frame or wall with a minimum distance between the two brackets The minimum distan...

Страница 9: ...ft heater into position and secure the 2 locking brackets to the mounting brackets using the screws provided Make sure the 2 pins on the locking bracket engage with the matching holes in the mounting...

Страница 10: ...set the timer from 0H 24H which is the number of hours it will run 0H will display and then adjust to the number of hours you would like to set using the up and down buttons 2 and 3 Note All HEATSTRI...

Страница 11: ...the minimum clearances The heater needs to be mounted on a rigid bracket or fixing The heater must not be mounted immediately below or in front of a socket outlet In case of a heater fault or damaged...

Страница 12: ...nt No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participa...