Thermofilm HEATSTRIP THN2000 Скачать руководство пользователя страница 3

 

 

 

Specifications 

-

 Australia

 

MODEL

 

POWER 

(WATTS)

 

CURRENT 

(AMPS)

 

DIMENSIONS 

(mm)

 

WEIGHT 

(Kg)

 

LEAD 

LENGTH 

(mm)

 

PLUG

 

THN2000

 

2000

 

8.3

 

900 x 130 x 89.5

 

3

 

2000

 

YES

 

MODEL

 

 

 

HEATER TYPE

 

Electric radiant, infra

-

red overheat heater with carbon filament element.

 

OUTPUT

 

800 / 1200 / 1600 / 2000 Watts 

 

POWER 

 

230

-

240 Volts Nominal at 

50

60 

Hertz, Single Phase

 

CONNECTION

 

3 Core Cable 2.5mm

2

 

APPROVALS

 

AUSTRALIA / NZ / EU

 

MOUNTING HEIGHT

 

MINIMUM

 

RECOMMENDED

 

MAXIMUM 

 

 

1.8 m

 

2.1 m 

-

 2.3 m 

 

2.5m Outdoors and 2.7m Indoors

 

MOUNTING OPTIONS 

 

 

Suitable for ceiling, wall, and beam mounting as well as suspension by chains & 

wires using standard brackets. 

 

PROTECTION RATING

 

IP55 Protection from water ingress from all directions

 

MATERIALS OF CONSTRUCTION

 

Anodised alloy casing with stainless steel grille (304SS)

 

THN2000

 

Содержание HEATSTRIP THN2000

Страница 1: ...Product Manual HEATSTRIP Nano Electric Heater Model No THN2000...

Страница 2: ...tant alloy it is suitable for use in most applications including difficult corrosive environments such as coastal areas For exposed or windy areas we would recommend the HEATSTRIP Intense or Max range...

Страница 3: ...40 Volts Nominal at 50 60 Hertz Single Phase CONNECTION 3 Core Cable 2 5mm2 APPROVALS AUSTRALIA NZ EU MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 1 8 m 2 1 m 2 3 m 2 5m Outdoors and 2 7m Indoors MOUNT...

Страница 4: ...over outdoor tables BBQ s lounges assembly lines or indoor work stations Often it is more practical and efficient to spot heat these areas Spot heating will help to reduce the initial capital cost as...

Страница 5: ...otprint is reduced The below table outlines the coverage HEATSTRIP Nano model in m2 based on 2 different scenarios For example in an outdoor area that is protected from prevailing winds by walls caf b...

Страница 6: ...For ceiling mounting heights more than 2 5m outdoors we recommend the use of the chains or wires to reduce the height of the heater to 2 1m 2 3m This will increase the effectiveness of your HEATSTRIP...

Страница 7: ...Wall Installation Ceiling Installation Angled Ceiling Installation Lights fans and sprinklers must NOT be below heater Surface Below Heater Lights fans and sprinklers must NOT be below heater Surface...

Страница 8: ...degrees to mount onto a beam it can also be used to suspend with chains The brackets need to be mounted onto a secure frame or wall with a minimum distance between the two brackets The minimum distan...

Страница 9: ...ft heater into position and secure the 2 locking brackets to the mounting brackets using the screws provided Make sure the 2 pins on the locking bracket engage with the matching holes in the mounting...

Страница 10: ...set the timer from 0H 24H which is the number of hours it will run 0H will display and then adjust to the number of hours you would like to set using the up and down buttons 2 and 3 Note All HEATSTRI...

Страница 11: ...the minimum clearances The heater needs to be mounted on a rigid bracket or fixing The heater must not be mounted immediately below or in front of a socket outlet In case of a heater fault or damaged...

Страница 12: ...nt No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participa...

Отзывы: