ELECTRICAL LOCKOUT/TAGOUT PROCEDURE
WARNING
: Before performing any
service that involves electrical connection
or disconnection and/or exposure to
electrical components, always follow the
Electrical LOCKOUT/TAGOUT Procedure.
Disconnect all circuits. Failure to comply
can cause property damage, injury or death.
The Electrical LOCKOUT/TAGOUT Procedure is
used to protect personnel working on an electrical
appliance. Before performing any maintenance
or service that requires exposure to electrical
components, follow these steps:
1. In electrical box, place appliance circuit breaker
into OFF position.
2. Place a lock or other device on electrical box
cover to prevent someone from placing circuit
breaker ON.
3. Place a tag on electrical box cover to indicate
that appliance has been disconnected for
service and power should not be restored until
tag is removed by maintenance personnel.
4. Disconnect appliance power cord from
electrical outlet.
5. Place a tag on the cord to indicate that unit
has been disconnected for service and power
should not be restored until tag is removed by
maintenance personnel.
MODEL
GALLONS
LITERS
PER
SHELF
(OZ)
125OC
1.5
3.78
14
200NDNL
1.75
6.62
6
200CT
1.75
6.62
6
250OC
1.65
6.62
20
250PNDT
2.1
7.95
6
BW3
1.65
6.25
6
BW4
1.7
6.44
6
FLUID CAPACITIES (STANDARD SHELF CONFIGURATION)
MODEL
GALLONS
LITERS
PER
SHELF
(OZ)
300NDNL
1.91
7.23
6
300CT
1.91
7.23
6
700NDNL
2.25
8.52
14
700CT
2.25
8.52
14
950NDNL
2.16
8.18
20
300OC
2.24
8.48
14
1600NDNL
2.1
7.95
6