HEAT TRANSFER FLUID MSDS

Dow Chemical U.S.A.

Midland, MI 48674

Emergency Phone: 517-636-4400

Product Code: 23545

Product Name:  PROPYLENE GLYCOL HEAT 

TRANSFER FLUID

Effective Date: 03-02-88

Date Printed: 06/02/88

MSDS: 000130
1. INGREDIENTS:

  Propylene glycol CAS# 000057-55-6 95%

  Dipotassium phosphate CAS# 007758-11-4 <5%

  Deionized water CAS# 007732-18-5 <5%

  This document is prepared pursuant to the OSHA Hazard 

Communication Standard (29CFR 1910.1200). In addition, 

other substances not ‘Hazardous’ per this OSHA Standard 

may be listed. Where proprietary ingredient shows, the 

identity may be made available as provided in this standard.

2.  PHYSICAL DATA:

  BOILING POINT: 370F, 188C

  VAP. PRESS: 0.22 mmHg @ 20C, 68F

  VAP. DENSITY: 2.62

  SOL. IN WATER; Complete

  SP. Gravity: 1,050 @ 60/60F, 16C

  APPEARANCE: Colorless.

  ODOR: Odorless liquid.
3.  FIRE AND EXPLOSION HAZARD DATA:

  FLASH POINT: 215F, 102C

  METHOD USED: COC

  FLAMMABLE LIMITS

  LFL: 2.6% @ 100C

  UFL: 12.5% @ 130C

  EXTINGUISHING MEDIA: Water fog, alcohol foam, dry 

chemical

  FIRE AND EXPLOSION HAZARDS: None.

  FIRE-FIGHTING EQUIPMENT: None.
4.  REACTIVITY DATA:

  STABILITY: (CONDITIONS TO AVOID) Stable over normal

  Operating temperature range of –30F to 250F.

  INCOMPATIBILITY: (SPECIFIC MATERIALS TO AVOID)

Oxidizing material.

  HAZARDOUS DECOMPOSITION PRODUCTS: None

  HAZARDOUS POLYMERIZATION: Will not occur,
5.  ENVIROMENTAL AND DISPOSAL INFORMATION:

  ACTION TO TAKE FOR SPILLS/LEAKS: Cover with 

absorbent material, soak up and sweep into bag.

6.  HEALTH HAZARD DATA:

  EYE: May cause slight transient eye irritation. Corneal 

injury is unlikely.

  SKIN CONTACT: Essentially nonirritating to skin on 

prolonged contact.

  SKIN ABSORPTION: A single prolonged skin exposure is 

not likely to result in absorption of harmful amounts. The 

LD50 for skin absorption in rabbits is >10,000 mg/kg.

  Repeated exposures may cause slight flaking, tenderness 

and softening of skin.

  INGESTION: Single does oral toxicity is low. The LD50 

for female rats is about 20.3 g/kg

  INHALATION: A single prolonged (hours) inhalation 

exposure is not likely to cause adverse side effects. Mists 

are not to be hazardous.

  SYSTEMIC & OTHER EFFECTS: Repeated excessive 

ingestion may cause central nervous system effects. No 

carcinogenic effects have been seen in long-term animal 

studies. Birth defects are unlikely. Exposures having no 

adverse effects on the mother should have no effect on the 

fetus. In animal studies, has been shown not to interfere 

with reproduction. Results of mutagenicity tests in vitro 

(test tube) and in animals have been negative.

7.  FIRST AID

  EYES: Irrigate immediately with water for at least 5 minutes.

  SKIN: wash off in flowing water or shower

  INGESTION: Induce vomiting if large amounts are 

ingested, consult medical

  INHALATION: Remove to fresh air if effects occur. Consult 

medical.

  NOTE TO PHYSICIAN: No specific antidote. Supportive 

care. Treatment based on judgment of the physician in 

response to reactions of the patient.

8.  HANDLING PRECAUTIONS:

  EXPOSURE GUIDELINE (S): Dow IHG is 10mg/m3 for 

propylene glycol mist. Dow IHG 440 ppm for propylene 

glycol vapors.

  VENTILATION; Good general ventilation sufficient.

  RESPIRATORY PROTECTION: No respiratory protection 

should be needed.

  SKIN PROTECTION: No precautions other than clean 

body covering should be needed.

  EYE PROTECTION: Use safety glasses.
9.  ADDITIONAL INFORMATION:

  REGULATORY REQUIREMENTS:

  SARA HAZARD CATEGORY: This product has been 

reviewed according to the EPA ‘Hazard Categories’ 

promulgated under Section 311 and 312 of the Superfund 

Amendment and Reauthorization Act of 1986 (SARA Title 

III) and is considered, under applicable definitions, to meet 

the following categories: A delayed hazard.

  SPECIAL PRECAUTIONS TO BE TAKEN IN HANDLING 

AND STORAGE: Exercise reasonable care and caution.

  MSDS STATUS: Revised Section 9

Содержание 1600NDNL

Страница 1: ...0NDNL 200CT 250PNDT Thermodyne Foodservice Products Inc 4418 New Haven Avenue 1 800 526 9182 Fort Wayne IN 46803 www tdyne com 300NDNL 300CT 300OC 700NDNL 700CT 725NDNL 950NDNL 957NDNL ADDFLUID ADDFLU...

Страница 2: ...ional Electric Code and or other local electrical codes Failure to comply with this procedure can cause property damage injury or death WARNING Before connecting the unit to the electrical supply veri...

Страница 3: ...rcuits are disconnected Failure to comply with this procedure can cause property damage injury or death WARNING Do not operate this equipment without properly placing and securing all covers and acces...

Страница 4: ...uid Light 11 Temperature Controller 11 Cooling Fan 12 Power Cord 13 POWER BOARD COMPONENTS 13 Solid State Relay 13 230VAC Float Board 14 300NDNL TWELVE BUTTON TIMER 15 PLUMBING COMPONENTS 16 B G Pump...

Страница 5: ...cal box cover to prevent someone from placing circuit breaker ON 3 Place a tag on electrical box cover to indicate that appliance has been disconnected for serviceandpowershouldnotberestoreduntil tag...

Страница 6: ...amage injury or death Removing the Power Head Lid provides access to allofthecomponentsofthePowerHeadAssembly 1 Perform the ELECTRICAL LOCKOUT TAGOUT procedure 2 RemovethePhilipsscrewssecuringthePower...

Страница 7: ...mponents 1 Cooling Fan 2 B G Pump 3 Reservoir Fill Cap 4 Reservoir Assembly 5 Contactor 6 Lighted Power Toggle Switch 7 Add Fluid Light 8 Temperature Controller 9 Solid State Relay 10 230VAC Float Boa...

Страница 8: ...DELIVERY MANIFOLD COMPONENTS 7 3 4 2 1 6 5 Figure 4 Delivery Manifold Components 1 Delivery Line 2 Teflon Washer 3 Shelf Plug 4 Power Cord 5 Delivery Manifold Assembly 6 Short Teflon Hose 7 Shelf Elb...

Страница 9: ...N MANIFOLD COMPONENTS 8 2 3 4 1 7 6 5 Figure 5 Return Manifold Components 1 Overflow Tube 2 Shelf Plug 3 Teflon Washer 4 Drain Tube 5 Drain Tube ON OFF Valve 6 Return Manifold 7 Long Teflon Hose 8 She...

Страница 10: ...front of the unit NOTE If the switch being removed is damaged it may be easier to break the spring tabs off of the switch rather than attempting to squeeze the spring tabs If this method is used remem...

Страница 11: ...eration Refer to the Changing the Heat Transfer Fluid section of this manual for procedures on draining and adding Heat Transfer Fluid 8 Remove the units from power 9 Replace the Power Head Lid 10 Res...

Страница 12: ...cuits are disconnected Failure to comply with this procedure can cause property damage injury or death WARNING Certain components may be hot if the unit was in operation prior to performing a procedur...

Страница 13: ...stic risers that allow for air flow on the underside of the board It is not necessary to remove the board when replacing one of its components however it may be necessary to loosen the screws that sec...

Страница 14: ...e Allow the unit to cool before beginning work 230VAC Float Board 1 Follow the LOCKOUT TAGOUT procedure usingtheproceduresprovidedintheLockout Tagout Procedures section of this manual 2 Remove the Pow...

Страница 15: ...ures section of this manual 2 Remove the Power Head Lid following the instructions provided in the Panels and Covers section of this manual 3 Tag and disconnect all of the component wires on the Power...

Страница 16: ...system the heat transfer fluid must be drained from the system B G PUMP NOTICE In BWSNDNL models the B G Pump and Heater Tank are located at the back of the unit Removal of the Back Panel is required...

Страница 17: ...e removing any sheet metal panels or servicing this equipment always perform the Electrical LOCKOUT TAGOUT Procedure Be sure all circuits are disconnected Failure to comply with this procedure can cau...

Страница 18: ...ls 17 Restore the unit s power check it for proper operation It may be necessary to add additional fluid after the unit has operated for several minutes 18 After the unit has operated for several minu...

Страница 19: ...ta Sheet provided in this manual for proper disposal of fluid Fluid Sensor Probes Figure 21 Fluid Sensor Probes 8 Disconnect the Fluid Sensor Probe lead 9 Remove the defective probe 10 Install the new...

Страница 20: ...he tags or circuit schematic reconnect the wires to the Snap Disc 12 Restore power to the unit 13 Close the fluid Drain Valve 14 Fill the Heater Tank and Reservoir Tank with fluid until the Low Fluid...

Страница 21: ...location of and colors of the Thermocouple wires on the Controller 10 Remove the wires for the Controller terminals 11 Remove the Thermocouple from the Heater Tank Thermocouple Figure 24 Location of T...

Страница 22: ...this manual 3 Removetheleftsidepanelusingtheprocedures provided in the Panels and Covers section of this manual 4 Locate the Drain Tube and place it into an empty pan 5 Remove the Heater Tank Cap and...

Страница 23: ...a new Pump Union Gasket reconnect the pump to the tank 21 Reconnect the Overflow Tube 22 Referring to the tags or the wiring schematic reconnect all of the wires and leads If the Thermocouple was remo...

Страница 24: ...function 6 Enter the manual control menu if the sensor has failed Unlock the Controller 1 Follow the LOCKOUT TAGOUT procedure using the procedures provided in the LOCKOUT TAGOUT Procedures of this man...

Страница 25: ...Alm 1 MAN C F Figure 30 Heater Tank Cap Reservoir Cap 6 Open the Drain Valve to drain the Heat Transfer Fluid 7 Discard the drained fluid refer to the Material Safety Data Sheet provided in this manu...

Страница 26: ...ill break down the protective film CAUTION Never rub in a circular motion CAUTION Never leave any food products or salt on the surface Many foods are acidic Salt contains chloride Forroutinecleaning u...

Страница 27: ...d Unit not reaching desired temperature Controller not set to 189 F Defective Controller Refer to Temperature Controller Set Up Procedures and set temperature to 189 F Refer to Temperature Controller...

Страница 28: ...28 WIRING SCHEMATIC CE Standard Wiring...

Страница 29: ...29 CE Standard Wiring TCB41 Controller...

Страница 30: ...30 Wiring CE ZYTRON...

Страница 31: ...kg Repeatedexposuresmaycauseslightflaking tenderness and softening of skin INGESTION Single does oral toxicity is low The LD50 for female rats is about 20 3 g kg INHALATION A single prolonged hours in...

Страница 32: ...32...

Отзывы: