THERMOCOAX Isopad IDR-SM Series Скачать руководство пользователя страница 7

 

__________________________________________________________________________________ 

7 | 

P a g e - S e i t e

 

 

8.

 

Never stick needles or sharp objects (or the 
like) in the product! 

9.

 

The  product  should  be  protected  against 
mechanical  damage  by  suitable  coverings 
(e.g. insulation and metal sheeting) 

10.

 

In  case  of  additional  safety  matters  a 
temperature  limiting  device  may  be 
installed 

to 

protect 

the 

application 

components from damage. 

 

  To  prevent  danger  an  RCD  or  ELCB 

  has to be installed!

  

 

Handling Information: 

 
11.

 

Never lift or pull the heating unit by its power 
cord or lead wire. 

12.

 

Never handle the heater while in operation. 

13.

 

When  removing  or  maintaining  the  drum 
heater,  disconnect  the  power  and  allow  the 
drum heater to cool down to ambient before 
handling. 

14.

 

Select  a  suitable  clean  location  below  the 
lowest expected content level of the drum. 

15.

 

If  the  drum  heater  is  located  outside or  in 
an area that it may be splashed with water, 
the  leads,  exiting  from  the  terminal  cap, 
must be directed to the ground. 

16.

 

Pull the spring to attach it to the opposite 
tab  shaping  the  drum  heater  tight  against 
the drum. (see Diagram 2) 

 

 

Diagram 1: An Example of Proper and 

Improper Installation 

 

 

 

Diagram 2: Spring Assembly 

 

  Warning:  

Do not use the terminal cap as a handhold 
when pulling the spring! 
 

  Caution:

 

To  avoid  external  touching  and  damage,  it  is 
required that within the application the product 
(component)  has  to  be  covered  by  a  metal 
sheeting  or  braid,  which  has  to  be  included  in 
the protective arrangement of Protection Class I 
(protective  earth)  according  to  VDE0100  or  to 
the relevant standards in your country and is to 
be 

taken 

into 

consideration. 

Metallic 

components coming in contact with the product 
have  to  be  incorporated  in  the  protection 
measures of Protection  
Class I (protective earth). For details please refer 
to  the  standard  VDE  0100  (Germany)  or  the 
relevant standards in your country. 
Additional 

to 

these 

instructions 

special 

requirements for the specific products are found 
on the product label or type plate and must be 
followed as well.  
The  products  are  designed  at  a  certain 
protection class. Considering that the product is 
not protected against hazardous body currents, 
it has to be installed in such a manner that any 
risk is excluded. 
In case of doubt or if necessary please contact 
us. (see last page for contact information) 

Содержание Isopad IDR-SM Series

Страница 1: ...1235 OMH58614B R12 0 OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG SILICONE DRUM HEATING BANDS SILIKON FASSHEIZB NDER SERIES SERIE IDR SM AUSF HRUNG VERSION B...

Страница 2: ...llation 6 Operation 8 Maintenance and Safety 8 Malfunction and Excessive Strain 9 Heated Media 9 Technical Data 11 DEUTSCH 12 Allgemeine Sicherheitshinweise 12 Allgemeine Produkt Informationen 13 Weit...

Страница 3: ...ance with any applicable specification _____________________________________________________________________________________________________ Haftungsauschluss Wichtig Alle Angaben einschlie lich der A...

Страница 4: ...rent breaker ELCB or RCD has to be installed for protection purpose This ELCB should represent a tripping current of 30mA To guard against electric shock the products have to be maintained and service...

Страница 5: ...tand temperature however depends on the specific operating conditions It may be influenced by the heat conductivity of the materials and media to be heated as well as by the throughput the ambient tem...

Страница 6: ...ture can be regulated via an external knob on a junction box mounted onto the surface of the product The products are equipped with power supply leads ready for termination It is important to determin...

Страница 7: ...the drum heater tight against the drum see Diagram 2 Diagram 1 An Example of Proper and Improper Installation Diagram 2 Spring Assembly Warning Do not use the terminal cap as a handhold when pulling...

Страница 8: ...hen connecting the product the requirements of the standards listed below in General Safety Instructions and Additional Safety Instructions have to be observed The maximum operating and withstand temp...

Страница 9: ...ve to be implemented and equipment authorized by the manufacturer When returned please always confirm decontamination status in written form and support this information directly with the returned pro...

Страница 10: ...ymbol indicates that the product should be disposed of separately to regular industrial domestic waste It is your responsibility to use this product and other electrical and electronic products only o...

Страница 11: ...ilicone Outer Sheath Glass fiber reinforced silicone Dimensions Ordering Information ItemType IDR SM 25 IDR SM 23 IDR SM 15 IDR SM 13 ItemNumber 791428 000 631912 000 118374 000 450166 000 Drum Size t...

Страница 12: ...n ELEKTRISCHES BETRIEBSMITTEL Das Produkt ist ein elektrisches Betriebsmittel Um Gefahren durch elektrischen Strom vorzubeugen darf es nur ber einen Fehlerstrom Schutzschalter mit einem Ausl sestrom v...

Страница 13: ...ebauten Thermostaten unterschiedlichen Betriebsspannungen unterschiedlichen Leistungsparametern Sie werden zum Aufheizen Temperaturhalten und Ausgleichen von W rmeverlusten an F ssern der Gr sse 110L...

Страница 14: ...e keine Kunststoffe oder nicht metallische Oberfl chen Die Oberfl che muss frei von Graten und scharfen Kanten Schwei spritzern Rost l farbe ect sein Falls es zum Auslaufen berlaufen kommen sollte sch...

Страница 15: ...hten Sie darauf das die angegebene Schutzart IP Schutzart geeignet f r die Einsatzumgebung ist Zum Beispiel sind gewebe isolierte Produkte mit einer niedrigen Schutzart eingestuft und sollten deshalb...

Страница 16: ...r Stellen Sie die gew nschte Temperatur mit dem Drehschalter an der Regeleinheit ein Bild 3 Stellknopf Die maximal zul ssige Temperatur f r den Silikonwerkstoff betr gt 218 C im Dauerbetrieb kurzzeiti...

Страница 17: ...turregel und Begrenzungs einrichtungen zu berpr fen und zu dokumentieren Produkte bei denen die Heizleiter sichtbar sind wurden berhitzt Sie sind sofort au er Betrieb zu nehmen und d rfen nicht mehr v...

Страница 18: ...sche Richtlinie 2002 95 EC und das deutsche Produktsicherheitsgesetz verlangen dass technische Ausr stung die direkt am oder mit dem Produkt und oder an der Verpackung mit diesem Symbol versehen ist n...

Страница 19: ...on Aussenmantel Glasfaserverst rktes Silikon Abmessungen Bestellinformationen Typ IDR SM 25 IDR SM 23 IDR SM 15 IDR SM 13 Artikelnummer 791428 000 631912 000 118374 000 450166 000 Fassgr sse typ 205L...

Страница 20: ...__________________________________________________________________________________ 20 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Страница 21: ...__________________________________________________________________________________ 21 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Страница 22: ...__________________________________________________________________________________ 22 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Страница 23: ...nforme aux norme s ou aux documents normatifs suivants Terms of the Directive s and Approval Data Bestimmungen der Richtlinie und Zulassungsdaten Prescription de la directive et donnees de reference a...

Страница 24: ...2012 THERMOCOAX ISOPAD 1235 OMH58614B R12 0 Thermocoax Isopad GmbH Englerstrasse 11 D 69126 Heidelberg Germany Tel 49 0 6221 3043 0 Fax 49 0 6221 3043 956 Mail to isopad info thermocoax com Web www t...

Отзывы: